59
4.1 F
UNCTION
MENU
4.1 F
UNCTION
MENU
ALS
20X
256
4.1.2
Notes on the description of
functions
The adjustment range or individual settings
available for a function are shown in square
brackets.
– For functions with individual values for
settings, the default value is printed in italics.
– Quotation marks are set around values for
settings that consist of more than one word.
4.1.3
LABEL SETUP menu
Load prod.profil
function:
– For loading product profiles from the internal data-
base.
– Product profiles contain product-specific settings.
– A maximum of 16 product profiles can be selected.
– The number of a product profile can only be select-
ed when there is already a profile saved under this
number.
Gap detect. mode
function:
– After one of the following events, the printer must al-
ways search for the punch, that is initialize the label
material: a
fter switching the device on; after
changing the label material.
– Settings: [Manual, „Autom. forward“]
Manual: The operator has to initialize the material
always manually by pressing the feed key several
times.
Autom. forward: The material initialization is always
done automatically, if necessary.
Dispense speed
function:
– Speed at which the label is dispensed
– Adjustment range:
ALS 204: [1.0…40.0] m/min; default: 10.0
ALS 206: [1.0…30.0] m/min; default: 10.0
ALS 256: [1.0…50.0] m/min; default: 10.0
Slew speed
function:
– Feed speed during initialisation
– Adjustment range:
ALS 204: [1.0…40.0] m/min; default: 1.0
ALS 206: [1.0…30.0] m/min; default: 1.0
ALS 256: [1.0…50.0] m/min; default: 1.0
Label pitch
function:
– Label pitch = label gap
– Adjustment range: [5.0…600.0] mm;
default: 100.0 mm
Lab. stop offset
function:
– Stopping position of the label at the dispensing plate
– Adjustment range: [0.0…999.9] mm; default: 20.0
Start offset
function:
The function has a different effect on slave machines in
tandem operation.
Standard operation or master machine:
– Distance between photoelectric product sensor and
apex of dispensing plate. The setting influences the
label position on the product.
– Adjustment range: [15.0…2999.9] mm; default: 15.0
Slave machine:
– Fine adjustment of the label position on the product.
– Adjustment range: [-30.0…+30.0] mm; default: 0.0
Product length
function:
– Start signals coming in during the set product length
are suppressed.
– Adjustment range: [0.0…1999.9] mm;
default: 0.0 mm
The Product length function is e. g. helpful for
products with uneven surface, which would trig-
ger several start signals.
Multi label mode
function:
– Settings: [
Disabled
, „x labels/start“]
Disabled: Each start signal causes printing of one
label.
„x labels/start“: Each start signal causes printing of
x labels; x = [2…20]
x > 3: The distance of all following labels after the
2nd label matches the value set in
LABEL SETUP >
Label 2 offset
.
The „Multi label mode“ function works only if a
standard signal input (M12 or D-Sub 15) is
used - it
doesn´t work
, if an Applicator Interface
is applied as signal input.