147
7.5 S
IGNAL
I
NTERFACE
ALS
20X
256
LTP and LTPV
[157] Pattern of control signals over time for LTP(V) applicators.
A
Duration is determined by label length and dispensing
speed. „Airstream Support“ switching to low means the label
is dispensed.
B
Duration t is determined by the backwards movement of the
applicator. The application cycle ends when the home posi-
tion signal is high again
C
Adjustable with “Blow on time” .
D
The output signal „Offline“ follows the input signal „Inhibit“.
E
The start signal is ignored because of the active „Inhibit“.
t
Start signal
Home position
Airstream support
Cylinder
(setable)
Vacuum
Blow on
(setable)
Offline
Cycle
Inhibit
Touch down
Additional signals with optional Applicator Interface:
B
D
A
C
E