7.5 S
IGNAL
I
NTERFACE
ALS
20X
256
7.5.7
Impact of the inhibit signal
The impact of the inhibit signal on the start signal is in-
fluenced by
MACHINE SETUP > On inhibit enter
and
MACHINE
SETUP > On inhibit leave
. Combining the settings of the two
functions has different effects.
To simplify the description in the following, abbrevia-
tions are used for the settings (see table). „A“ refers to
the rising slope, „B“ refers to the dropping slope of the
inhibit signal.
[166] Example for setting combination A1B1 and A1B2.
– A = relative position of the product sensor at the time
of
rising
signal slope
– A´ = relative position of the dispensing edge at the
time of
rising
signal slope
– B = relative position of the product sensor at the time
of
dropping
signal slope
– B´ = relative position of the dispensing edge at the
time of
dropping
signal slope
Function
Setting
Abbrev.
Signal slope
Effect
MACHINE SETUP >
On inhibit enter
„Do saved starts“
A1
Low-high
Queue is processed
„Del saved starts“
A2
Queue is deleted
MACHINE SETUP >
On inhibit leave
„Do saved starts“
B1
High-Low
Queue is processed
„Del saved starts“
B2
Queue is deleted
A
B
A'
B'
Start signal
Inhibit signal
Product sensor
Dispensing edge
= Product will be labelled
= Product will not be labelled
Содержание ALS 204
Страница 1: ...ALS 204 206 256 SERVICE INSTALLATION MANUAL Labeller Edition 8 3 2012 Original version ...
Страница 2: ......
Страница 125: ...125 7 ELECTRONICS DESCRIPTION 7 3 CIRCUIT BOARDS ALS 20X 256 Layout diagram 125 Layout diagram for the CPU board ...
Страница 128: ...128 7 ELECTRONICS DESCRIPTION 7 3 CIRCUIT BOARDS ALS 20X 256 Layout diagram 129 Layout diagram for motor driver board ...
Страница 223: ......