Страница 1: ...Q 25 Q 45 104304 104306...

Страница 2: ...rtscher GmbH Franz Kleine Str 28 D 33154 Salzkotten Germany Phone 49 5258 971 0 Fax 49 5258 971 120 Technical Support Hotline 49 5258 971 197 www bartscher com Version 1 0 Date of preparation 2021 12...

Страница 3: ...Beschr eibung...

Страница 4: ......

Страница 5: ...ery 10 Production cycle start every 0 5 Ice production ON Alarm blackout ON 5 OFF Cleaning cycle ON 3 OFF ATTENTION Should subsequent alarms appear contact the service company Setting Storage containe...

Страница 6: ......

Страница 7: ...otection 6 2 3 Declaration of Conformity 6 3 Transport Packaging and Storage 7 3 1 Delivery Check 7 3 2 Packaging 7 3 3 Storage 7 4 Technical Data 8 4 1 Technical Specifications 8 4 2 List of Componen...

Страница 8: ...s included in this manual is a prerequisite for safe and proper handling of the appliance Additionally accident prevention occupational health and safety and legal regulations in force in the area the...

Страница 9: ...nt Too high a mains voltage or incorrect installation may cause electric shock The appliance may be connected only if data on the rating plate correspond with the mains voltage To avoid short circuit...

Страница 10: ...f coolant leakage pull the plug from the socket Remove all sources of ignition in the vicinity ventilate room and contact technical service Avoid coolant getting in contact with eyes as it may cause s...

Страница 11: ...attempt to repair the appliance on your own Do not introduce any changes in the appliance nor modify it 1 3 Intended Use As described below every use of the appliance for a purpose differing and or di...

Страница 12: ...troduced by the user usage of unapproved spare parts We reserve the right to introduce technical modifications to the product intended for improvement of the appliance and its performance 2 2 Copyrigh...

Страница 13: ...used to store the appliance when relocating or when shipping the appliance to our service point in the case of any damages The packaging and its elements are made of recyclable materials Particularly...

Страница 14: ...e cube sizes 1 Ice cube size W x D x H in mm 30 x 26 x 40 Ice cube weight in g 17 Ice cubes output work cycle 15 Max output in kg h 25 24 Storage container capacity in kg in ice cubes pcs 10 588 Coola...

Страница 15: ...capacity in kg in ice cubes pcs 16 941 Coolant amount in kg R290 0 080 Climate class SN Water connection 3 4 Water outlet in mm 20 Connected load 0 36 kW 220 240 V 50 Hz Dimensions W x D x H in mm 50...

Страница 16: ...liance 1 Housing 2 Control key 3 Ice shovel holder 4 Water drain opening 5 Temperature probe 6 Water pan 7 Storage container 8 Storage container door 9 Power cord with mains plug 10 Water connection 1...

Страница 17: ...with the gear motor by means of a lever After separation ice cubes move to a tilted grate inside the tank and then they are transported to the storage container s shelf below Water remaining in the pa...

Страница 18: ...pliance remove all external and internal packaging elements and shipment safeguards CAUTION Choking hazard Prevent children from accessing package materials for instance plastic bags and EPS If the ap...

Страница 19: ...de for the following conditions ambient temperature may not drop below 10 C 50 F and rise above 43 C 110 F water temperature may not be below 10 C 50 F nor above 32 C 90 F Fig 4 at the beginning of th...

Страница 20: ...e electric connections 3 Connect the enclosed 3 4 water drain tube to the water connection 4 Connect the other end of the tube to the water connection at the back of the appliance NOTE Due to practica...

Страница 21: ...appliance is brought from the outside to a room leave it for a few hours to heat up and reach the room temperature before switching it on Before connecting the appliance to the power supply wait 1 hou...

Страница 22: ...the Standby mode and switch the appliance on press the control key for at least 3 seconds and wait for a long acoustic signal confirming the appliance is on Fig 11 NOTE We recommend not to use ice cub...

Страница 23: ...eriod Fig 11 The control key lights up in white or red 2 To increase the set temperature press the control key Fig 11 repeatedly and try to change the key colour to red 3 To reduce the temperature pre...

Страница 24: ...alarm optionally OFF ON 1 Power supply malfunction alarm or no electric supply OFF x 1 ON 5 Condenser high temperature alarm ON OFF High pressure alarm ON OFF Gas charge phase signal ON 1 ON 1 No wat...

Страница 25: ...rains are not the reason for leaks If the appliance produces too little ice check the condenser for cleanliness and the coolant for leaks 6 Cleaning 6 1 Safety Instructions for Cleaning Before cleanin...

Страница 26: ...disconnect it from power and water supply remove the produced ice from the storage container drain the entire water perform thorough cleaning leave the door lid of the storage container slightly open...

Страница 27: ...s of possible causes and solutions to malfunctions or errors during operation of the appliance These malfunctions may be cleared by a qualified refrigeration technician In such a case provide article...

Страница 28: ...nance alarm Appliance continues operation Contact the service company Reset the alarm by touching the control key for 10 seconds Condenser high temperature alarm The appliance stops the condenser s fa...

Страница 29: ...apsed Discharge pump alarm Clogged discharge opening Check the appliance for obstacles in discharge route Discharge pump damaged Replace the discharge pump Too long a defrosting process alarm Defrosti...

Страница 30: ...on 8 Disposal Electrical Appliance Electric appliances are marked with this symbol Electrical appliances must be disposed of and recycled in a correct and environmentally friendly manner You must not...