Installation and operation
14 / 30
104304
EN
• Level the appliance (Fig. 3). If the appliance is not levelled, it may negatively
affect its functionality, as well as water supply.
Remove Transport Safeguards
1. Remove screws fixing the upper cover.
2. Remove the upper cover.
3. Remove transport safeguards of the paddle system motor. Observe indications
on the affixed sticker (Fig. 9).
4. Screw the top cover to the appliance.
Water Connection
1. Install the appliance near a water connection.
ATTENTION!
Connect the appliance only to a supply connection of potable water.
Otherwise install a water purification appliance.
2. Execute water connections before you execute electric connections.
3.
Connect the enclosed 3/4” water drain tube to the water connection.
4. Connect the other end of the tube to the water connection at the back of the
appliance.
NOTE!
Due to practical and safety reasons we suggest to integrate a shut-off
valve, which is not a part of the delivery (Fig. 7):
1. ON/OFF switch; 2. Socket; 3. Plug; 4. Water connection; 5. Shut-off valve;
6. Water drain from condenser: water cooling version;
7. Water drain from storage container; 8. Water drain to open water trap.
Water Drain
1. Connect the enclosed water drain tube to the drain connection at the rear of the
appliance.
2. The other end of the water drain tube introduce into the open water trap (Fig. 7).
NOTE!
To provide for perfect water drain, the water drain tube must be routed at
the inclination of at least 3%; at the same time make sure it is not tangled
nor bent.