background image

GEM and MFI Cleaning and Sanitizing

Please refer to the Ice-O-Matic website for the most current version of 
these instructions

.     

www.iceomatic.com/Service-and-Support/Service-Documentation

IOM recommends cleaning and sanitizing be performed every 6 months
but no more than once per month.

CAUTION: Do not perform these cleaning procedures unless you are 
wearing protective eyewear and gloves.

Before beginning the cleaning and sanitizing process, all ice must be 
removed from the  ice bin.

Cleaning the Ice Machine. 

1.

Remove all ice from the bin or dispenser.

2.

Remove front panel by removing 2 Philips head screws.

3.

Remove Air Filer by lifting the filter upward.

4.

Turn ICE/OFF Switch to the OFF position

5.

Remove the cover from the water reservoir and turn water off to 
prevent water from entering the reservoir. 

6.

Use the drain tube to remove the water from the reservoir and 
evaporator by unclipping the tube and removing the plug from the 
end of the tube.  Drain the water into the bin or a bucket.  Return 
the drain tube to its normal position and replace the end cap. 

7.

Mix approved nickel-safe ice machine cleaner (diluted per 
manufacturer’s instructions) to yield one gallon of cleaning solution 
and pour into the water trough.  Refer to 

www.iceomatic.com

for 

approved chemical formulations.

8.

Slowly pour the cleaning solution into the water reservoir until full. 
Allow cleaner to soak for 15 minutes .

9.

Turn ON/OFF switch to the ON position. 

10. The ice machine will begin to make ice with the cleaning solution. 

Continue to add more cleaning solution to maintain a full reservoir. 

11. After all of the cleaning solution has been used and the reservoir 

has about ½” of solution remaining, turn the ON/OFF switch to the 
OFF position. 

12. Wash the water reservoir with remaining cleaner then drain the 

water reservoir and evaporator assembly with the drain tube. 

13. Rinse the water system by filling the reservoir with fresh water and 

draining the water again.  Repeat this step.

14. Return the drain tube to its normal position and replace the drain 

plug end cap. 

Sanitizing the Ice Machine is required after cleaning. 

15. Mix approved sanitizer (diluted per manufacturer’s instructions) to 

yield one gallon of sanitizing solution. 

16. Slowly pour the sanitizing solution into the water reservoir until full. 
17. Repeat steps 9 through 13 above.
18. Rinse the water system 2 additional times to ensure all sanitizer has 

been removed.

19. Return the drain tube to its normal position and replace the drain 

plug end cap.

20. Turn ON/OFF switch to the ON position and allow the machine to 

make ice for a minimum of 15 minutes to ensure all sanitizer has 
been removed from the reservoir and discarding the ice.

Remove and discard all ice in the storage bin. DO NOT USE any ice 
produced from the cleaning  or sanitizing solution.

Proceed to side 2 for  Bin and filter cleaning.

8

7

6

5

4

3

15

2

1

3/8/2016