SECTION V: WIRING DIAGRAM
Figure 9: AV-2016D and AV-2016DP Wiring Diagram
C2
+
+
C3
C7
+
+
C8
C10
+
+
C12
+
+
C13
+
+
C14
+
+
C15
C16
+
+
C17
+
+
C18
C19
C32
C33
C61
C62
C64
C65
C66
C68
C69
D40
+BATTERY
-BATTERY
J1
Q32
R1
R2
R3
R4
R5
R6
R8
R9
R10
R11
R12
R13
R14
R15
R16
R17
R29
R33
R34
R35
R42
R43
R44
R71
R73
R74
R89
R91
R92
R93
R94
R95
R97
R98
R99
R100
R101
R102
R120
R122
R127
R128
R131
R132
R135
R183
U3
U4
U5
U8
U11
U14
U15
U16
U17
U20
VA1
VA2
VA3
VA4
VA5
VA6
VA7
Y1
C11
+
D2
D3
D4
D5
R22
R24
R121
R123
R124
R125
VA8
Q31
CB
E
U12
U13
U18
6116
U2
D14
D16
D17
R36
X1
U19
R32
R31
C9
U7
TZ1
RF2
RF1
R134
R133
R30
R28
R27
R18
Q2
C
B
E
LD1
K3
D13
C1
D25
R62
R20
R26
R7
D1
D6
D7
D8
D10
D11
D12
D34
R90
C20
+
+
C21
+
+
R38
R39
R45
U1
C60
+ +
Q5
D32
U6
U9
R49
U21
U22
JP1
R47
R50
R19
To AV-816 EXPANDER
AV-GAD SYSTEMS LTD.
2000 SERIES/AV-2016
+12V
ZONE 1 TO 16
1
2
3
4
-V
5
6
7
8
-V
9
10
11
12
-V
13
14
15
16
-V
TEL LINE
PHONES
SLO-1
SLO
A1
A2
ON
RX -V
OR
-V
+12V
KEY
SIR2
SIR-
SIR1
AC
AC
16V
YE
BAT. FUSE
C22
D9
D15
D21
D22
R37
R51
R53
R54
RF4
VA9
R59
D20
Q1
CB
E
R41
D19
R40
D23
RN1
R52
R60
R136
Q4
C37
C31
+
+
RF3
D18
SERIEL IN/OUT
E
C
B
+5V
TX
R72
-12V
*
7
4
1
0
8
5
2
#
9
6
3
Siren
Shunt
Display
Status
Delay
Delete
Chime
Test
Program
Reset
Shunt
Telephone
ZONE
DISPLAY
EASYLOADER AV-701
AV-GAD
PHONES
TEL. LINE
AV-GAD
AV-GAD
220V
Fuse 0.5A
A1 Remote Indication
A2 Remote Indication
SLO-1 Selective Indication
ON Indicates Arming
All zones are refered to -V
To 220V AC
KEY
-
+
BATTERY
COLD WATER
GROUNDING
USE 3M"M
WIRE, RUN
5 METER MAX.
-V
SLO Selective Indication
EOL Resistors are 2,220K Ohms
SVM (voice module)
WARNING
:
To prevent
electrical shock,
disengage the
System and
disconnect the
telephone line
before servicing
this unit.
5
•
EOL Resistors
: Use 2200 ohms (2K2) resistor.
6
•
Keypad
: Connect maximum of four AV-701 or AV-706, 707 keypads.
7
•
Remote Arming
: Use spring-return lock type; run wires of 20 meters
maximum, or use wireless remote device to Arm/Disarm System.
8
•
Sirens
: Connect horn-type siren (speaker) or 12V DC type (Bell). If using Bell
adhere to maximum ratings (see Siren paragraph).
9
•
Tel Line
: Dialing is applicable for DTMF and PULSE telephone systems
.
1
•
Transformer
: Connect fused (0.5A) transformer to a non-switched main outlet.
Make sure to use fused main
not
connected to an automatic switch.
2
•
Grounding
: Connect Ground from the board to Cold Water pipe (ground),
using 2-2.5 m
2
wire, as short a length as possible, and no more than 4 meters.
3
•
Fuses
: All fuses are Electronic type.
4
•
Battery
:
Non-replaceable type Fuse. Recommended Battery: Sealed Lead
Acid type 12V - 7.2 AH.