![AV-GAD EasyLoader AV-2016D Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/av-gad/easyloader-av-2016d/easyloader-av-2016d_installation-and-operation-manual_3023938022.webp)
22
is 50 seconds). The siren sound will stop ten (10) seconds before the end of the call and a
greeting tune will be sounded, after the greeting tune enter your code followed by #.
To stop the dialer enter 6#, to get panel status enter 7#, to disarm the panel enter 2#. To end the
process press 9#.
The control panel will answer the call after the number of rings programmed at address 091 (or
following the “bypass answering machine" procedure).
Commands
Each command must be followed by the '#' key (Enter) in the remote phone. The control panel
waits 4 seconds between the keys typed. When this time expires, previous keys input will be
discarded.
The key '*' cancels previous input. It’s recommended to start with "learn" function [8X #] to
identify the various confirmation tune.
The commands:
[0 X #] -
Bypass zone
(# is the Enter key)
X is Bypassed zone 1 to 8
To clear all bypassed zone: 0 9 #
The zone bypass command is valid only when the system is in Disarm position and not in Alarm
position.
[1 #] -
Arm the control panel
. The control panel arms even with open zones. After the arming,
a confirmation tune followed by an "armed" tune heard ("Armed" tune: Short beep followed by
a long tone.).
The user can wait a few seconds to be sure that no alarm caused by open zones. In this case, an
Alarm tune (siren sound) sound.
[2 #] -
Disarm control panel
. When control panel disarmed A confirmation tune followed by a
"disarmed" tune heard ("Disarmed" tune: Five short beeps).
[31 #] -
Activates A1
output for 3 seconds (enabled by programming 076-2)
[33 #] -
Activates
SLO 1
output for 5 seconds, keypad sounds 7 short beeps (enabled if SLO 1
is not used with zones alarm events or for Chime activation)
[6 #] -
Stops dialer.
The dialer will stop calling the programmed telephone numbers. This will
affect only the current dialing process. A new alarm will re-start the dialer.
Note that if the user answered a call from the panel or called the panel during a dialing period
without Arming/Disarming/Stopping the dialer, the dialer will restart the cycle from the
beginning.
[7 #] -
Check control panel status
. The control panel will answer with an Armed or Disarmed
tune followed by an Alarm tune if it is in an alarm condition.
[7 and 7 #] -
First Alarm Zone Report,
beeps count for the zone number. Report user the first
zone that caused alarm. Arming or Disarming clears the First alarm zone reported by DTMF.
Zones 1 - 10: 1 to 10 short high tones
Zones 11 - 19: One long low beep for 10 followed by 1 to 9 short high beeps.
For example, zone 14: Reported as one long - low beep followed by four (4) short beeps.
Zone 20: Two long - low beeps.
Zones 21 - 24: Two long - low beeps followed by 1 - 4 short high beeps.