Zone Wiring Mode
Via programming, select either End-Of-Line (EOL) Resistor Protection, or non-EOL mode.
If EOL mode selected, install EOL Resistor (2.2K/0.25 or 0.5W) inside the detection device
(e.g. PIR, Magnetic Switch).
To enable EOL mode programming and resistors required.
To enable the Tamper Alarm of each zone, refer to the programming table and set the required
zone by programming address number 144, 145, 146, 147.
Wiring details are available in the AV-2016 manual, see Double-Zone wiring chapter.
Programming
Program the ‘Zone in Use’ feature for the required zones (address 102 and 103). By default,
program zones 1-16 set as ‘Zone in Use’.
2.3
AV-2055, 2088D Wiring
The AV-2088D contains eight zone terminals. Via programming, the panel becomes 16 zones,
when zone doubling used. Adding the AV-208 the panel expand to 32 zone. Refer to figure 3.
AV-2088D is compatible with AV-701, AV-702.
Figure 3: Wiring AV-2088D
AV-2055D:
Default is five zones. To expand to 13 zones add the AV-208 expander board (not
supplied). Zones on the expander counted zone 6 to zone 13. In ABS box insert the AV-208 in
the left side of the box (grooves to fit), in metal box use the four supplied spacres).
In "Double Zones" mode (074-8, must use EOL resistors) both board and expander zones are
doubled. Program the relevant zones as In Use (address 101), it provides 10 zones from the
board (1 - 10).
Zone 6 connected to terminal 1, 7 to 2, 10 to 5.