28
Upon display of last event, if an attempt is made to move forward (key 2), a blank sign ‘-‘ is
displayed, along with a warning beep indicating that this is the last event. Press key 8 may to
move backward. If no key is pressed, Event History stops and system returns to Use mode.
When starting History Events mode the events are displayed from the beginning to end without
any break, until any browsing key is pressed.
During History Events, browsing system will respond only to alarm or panic, Arming
denied.
Alarm or Panic during History Event mode will quit this mode and system will set to Use
Mode (normal operation mode).
For easier detailed alarm history, use the downloaded from panel to remote computer. History
queue log of up to 99 events are displayed at the keypad and in the
EasyLoad
PC software.
4.
0
Shunt
and
1
Siren
Display and Setting of System Time:
Hold down key ‘0’ and then
hold-down key ‘1,’ 3 LEDs will blink. Wait for the display of system time in 4-digit format.
To set new time, hold down key ‘0’ and then hold down key ‘1.’ Do not wait for time display;
enter the new time in 24-hour format. The local clock time is not stored in system memory;
adjust clock after power-up. After powering-up system, time is reset to 00:00, ‘h’ will be
displayed to remind user to set time; ‘h’ will disappear after setting the time. If Auto-Arming
enabled the clock setting is from user Programming mode only, refer to Auto-Arming section.
5.
0
Shunt
and
2
Shunt
Display
Display and Setting of System Date:
Hold down key ‘0’ and then
hold-down key ‘2’; 3 LEDs will blink. Enter date: ‘dd mm yy.’ The up and download PC
software displays time and date, along with event history.
The local date is stored in system memory; adjust date after long power-fail.
Years 78 through 99 translated as 1978 to 1999
Years 00 through 77 translated as 2000 to 2077
5.
0
Shunt
and
3
Status
Concise History of Tampered Zones:
Hold down key ‘0’ and then
hold down key ‘3’ to display the Tampered zone alarm sequence.
New alarm will create a new history event instead of old one.
6.
0
Shunt
and
4
Delay
Delete
Reset Events Memory (history):
Hold down key ‘0’ and then hold
down key ‘4’ to clear all events from memory. Starting version 2.09, cannot erase the history
log (former command ‘0’ + ‘4’).
Instead, during the installer-programming mode, clear history by command 200+04.
7.
0
Shunt
and
5
Chime
Display Last 2 Users:
Hold down key ‘0’ and then hold down key 5
to display user number and System opening or closing time.
‘o’ is displayed for Opening (Disarming); ‘c’ is displayed for Closing (Arming).