Symptom
Possible Cause
Remedy
Buzzer sounds in disarm mode
Hold-down function was
entered or Day zone
triggered
Arm and then disarm to cancel
chime and fault find features,
or hold-down key ‘9’ to reset
day zone alarm
User code is unknown
User forgot the Arming
code
1) Enter to installer
programming mode, to address
099. Set new user code.
Set system to default codes (If
programmed so).
2) Refer to ‘Resetting Codes to
Default feature, page 30
Panel’s PCB is getting hot,
system doesn’t function
normally
•
AC power is too high
•
Power supply
overloaded or faulty
battery (shorten)
•
Measure the low AC power;
should not exceed 17V
•
Try to disconnect sensors,
keypads or other loads that
consume high current