![AV-GAD EasyLoader AV-2016D Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/av-gad/easyloader-av-2016d/easyloader-av-2016d_installation-and-operation-manual_3023938051.webp)
51
The system status (Armed or Disarmed) reported also if extended, or if two-digit format selected.
For example: ‘A’ in address 236 for Armed, and ‘D’ in address 254 for Disarmed.
Signal Test enabled by days of the week programmed at address 077. As 1 is Sunday, 7 is
Saturday. An eight (8) enable test for all the week days, 0 clear all.
Even if the test programmed at each hour, it will perform only on the programmed days.
Address: 072, 073, 077, 236, 237, 254 and 255.
Telephone Line Monitor -
Telephone line test will begin 60 minutes after boot-reset (power on)
and 1 minute after each arming. If address 083 (dial tone detection) is programmed as 0 (zero), the
telephone line test will not be performed. By selecting the test, Abort Delay forced 00 at 069.
Address 096 - Time interval between telephone line tests - in minutes. Range 00-99.
If ‘00’ is selected no test performed (but failure to get a dial tone when dialing will cause a
“Phone line fault" event). To test the telephone line when the panel is Disarmed, program 075 – 6,
see also 075-7.
Zone In Use -
A zone programmed as an ‘In Use Zone’ enables activation of the programmed
zone. This feature eliminates the need to bypass zones by wire or End of Line Resistor.
Address: 100-103.
2.7
Step - By - Step Programming
Entering Installer (Engineer) Programming Mode Via AV-701 or AV-702 Keypad
Easy Tip:
You may program any address by entering the address, followed by the value in
sequence.
Power up by connecting AC power with or without battery.
1. Hold down keypad key
8
Program
(hold-down function).
2. While four LED's are blinking enter programming code (‘1 9 9 4’)
1
Siren
9
Reset
9
Reset
4
Delay
Delete
.
3. If code is valid ‘P’ will be displayed. The two left LED's (Red & Green) blink to indicate that
system is waiting for a new address.
4. Enter the address you want to program (see programming sheet). Current value of address is
displayed, and LEDs will blink.
Note:
Blinking of 2 left most LEDs
,
means
system is waiting for new
address
to be entered;
Enter a 3 or 2-digit address (according to address length.)
Note:
3 blinking LEDs means
system is waiting for new
value
to be entered;
Enter a 2-digit value, or as required.
EXAMPLE 1:
System in program mode; ‘P’ is displayed and the two left-most LEDs are blinking.
1. Program zones 1 and 4 as ‘Exit/Entry Delayed 1’ zone.
2. Address 108 represents the ‘Exit/Entry Delayed 1’ zones.
3. Press
1
Siren
0
Shunt
8
Program
; current value of this address is ‘1’ (default program.)
Three LEDs will blink and a ‘1’ will be displayed (default program).