Panic Alarm
- Holding down * and # keys will trigger Keypad Panic alarm; H is displayed (zone
‘H’).
To reset the alarm enter a valid code. Panic Zone included at address 196-199, the default is 0.
The Panic zone provides to use remote panic buttons; in previous version, only Panic from keypad
was available. When AV-707B keypad is interfaced Panic, Medical and fire button are included,
to enable them program at 074 a 7.
Contact ID format reports Panic alarm to central station. Siren sounds. If Siren (not Bell) in use,
the sound is different, not the same sound as Burglary alarm. Panic alarm recorded in history, in
LED keypad displayed as H (z). (Z: Zone number, 1-32). For Silent Panic alarm, remove siren and
buzzer activation by programming the Panic Zone so. Address: 196-199.
Re-Dial Cycles
- The number of times dialer or communicator will dial the programmed
telephone numbers. Address: 087. (Recommended value: 3)
Report Opening/Closing (Enable-Disable) -
This feature enables or disables the Opening and
Closing report for central station. Applicable for residential installation when Opening and
Closing reports are not required. Address: 072.
Report Bypassed Zones at Arming (Enable-Disable)-
Insurance companies require this feature
in certain areas. Address: 072.
Siren Time
- Determines the duration of the alarm when zones are activated. Fire and Panic alarm
issues a modulated 2-tone siren. 24H and Burglary alarm issues a modulated 3-tone siren.
Modulated tones are disabled when Bell Mode is programmed (Address 072).
A programmed value of ‘0’ will issue an inaudible alarm. Address: 063.
Swinger Shut-Down Zone
- Zones 1 to 32 which have been programmed as Swinger Shut-Down
zones will reset twice (3 alarm cycles). This feature prevents repeated false alarms and lowers the
security level. Address: 132, 133, 134,135.
SVM (Synthesized Voice Module) Module -
Optional module that enables transmission of
recorded message upon alarm. Special interface is requires connecting the SVM module. To
trigger the SVM unit, program address 072, location 7. SVM pack contains the wiring
instructions.
Signal Test to Central Station (Enable-Disable) -
This feature enables setting up time of signal
test, which is transmitted by the communicator at the required time. The time is set at address 014
in a 24-hour format. Test performed 1 minute after: Powering-up, disarm, programming exit.
For example: If the transmitting time is every night at midnight, enter 0000. To enable the signal
test, program ‘4’ at address 072.
Address 073 ‘2’ enables the signal test every hour. Other periodical or manual via keypad, CS
tests are not possible. (CS is shortening of Central station).
The test signal is on automatically every 24 hours to confirm that system is operative.