Indicates zone's Tamper alarm 

 

U

 

Update

 

Confirms programming updating 

 

    

 

User

 

‘u’ (user) followed by user number when events log is 
displayed and system is in user code programming 
mode 

 

 

           

      

 

 

Arming Denied 

or 

AC Fail

 

 displayed upon Arming attempt with non-delayed 

(instant) zones in trouble. 

 displayed upon and after AC fail while system is 

Armed or Disarmed 

 

1.6 

ˆ

  Arm and Disarm System via AV-701/702 Series Keypad 

 
1.  Make sure that all burglary zones are closed. 
2.  The green Status LED indicator will remain lit (not blinking) while all zones are closed. 
3.  Green indicator will blink when a zone is troubled. Press key 3 for display of troubled zone 
  

on keypad. An open delayed zone (exit zone) will also cause indicator to blink. 

 

 

(3 lines) indicated at arming of system if instant zones or 24-Hour zones are troubled 

   (blinking Green LED indicator followed by 

 in display and 5 warning beeps); open zones 

  

will then be displayed. 

4.  To bypass a zone, press key 0 (Bypass Key), followed by the zone number. 

To bypass a pre-programmed group of zones (requires programming), press 0 (zero key) 
twice (short press). AV-2016DP/2.09: Enter your code then press key 3. 

5.  Arming: Enter the Arm/Disarm code (No. 1 default code is 1,2,3,4), the Red Armed  
 

indicator will light up. If any zone (not Delayed or Follower) is troubled, 

 will be displayed 

 

and system will remain Disarmed.  

 

System Arming is disabled if Instant zone troubled. 

6.  For Instant Arming, press key 5 (if previously programmed). See address 071.  
 

Red ‘Armed’ indicator should light up. The system is now armed. 

7.  Disarming: you may have to hold-down key 9 (reset) to clear any previous key presses, and  
 

then enter arm/disarm code (or turn optional key-switch); the Red ‘Armed’ indicator will go 

  

off. 
Alarm history displayed upon disarming. If a 24H alarm occurs during Disarm mode Enter 
Arm/Disarm code. 

8. 

Keypad Keys Self Locking:

 In Armed and Disarmed mode, after six attempts to enter fault 

code, the keys will not react to any key press. This prevents code learning or other code 
break exigency. After a 30 seconds delay, the keys will revert to code entry mode. Each new 
erroneous code will lock system for another 30 seconds. 

9.

   Auto Arming 

 

Programming the time for Automatic Arming:  

 

- By Installer

: Program (or display) the hours and minutes at address 016. 

- By User

: Enter to user programming mode. Hold down '8' ('A' is displayed); type hour and 

minutes in 24 hours format. To display, hold down '8' and wait. To disable Automatic 
Arming program 0000. 

Содержание EasyLoader AV-2016D

Страница 1: ...for LED keypad Integrated Alarm Control Communicator Installation and Operation Manual Version 3 05 Edition I This product is subject to continuous enhancements and therefore specifications may be cha...

Страница 2: ...1 Sirens 15 3 2 Remote Indication Terminals 16 3 3 Wiring and Connection of Relay Module 17 4 WIRING AND POWERING UP 17 4 1 Grounding Lightning Protection 17 4 2 Back up Battery 18 4 3 Before Powering...

Страница 3: ...ing Telephone Numbers 57 2 9 2 User Programming of Follow Me Telephone Number 57 2 10 Quitting Programming Mode 57 2 11 Verification of Current Programming 57 2 12 Downloading from a computer 58 3 PAR...

Страница 4: ...supply improved electronics and additional signaling indicators The 2000 Series innovative keypads AV 701 AV 702 are unquestionably the most user friendly remote station designed to enable control of...

Страница 5: ...ng and Singapore Signals to central station monitoring via wire or wireless Up and Download from a computer or via telephone line Up to 250 alarm logs with event time Up to 8 or 16 user codes each cod...

Страница 6: ...able Programmable Bell Mode SPR output toggle mode via hold down key Remote Signals 24H zone Alarm On Off Arming Disarming indication Central station Signal Test Transmitting time is programmable Pani...

Страница 7: ...ected to panel via 4 terminal wires Compatible with AV 2016D AV 2016DP AV 701TI AV 701TP Identical to AV 701TS with additional timed backlight illumination AV 701TP includes Tamper protection 5005TER...

Страница 8: ...hms 0 25W 5 Zone Loop Voltage 5 to 6 5V DC Zone Loop Current 3 mA with End Of Line Resistor Line Protection Zone line shorting cutting high voltage lightning protection RF Metal Screen Electro Static...

Страница 9: ...hen the alarm will refuse to arm because a zone is troubled Complete the power supply siren keypad and strobe wiring and for the moment connect ALL the zone terminals to V This will simulate a system...

Страница 10: ...ey 1 refer to page 26 Select a mounting location accessible to the following 1 A continuously powered non switched AC power source compatible with step down transformer Make sure the mains 110 or 220V...

Страница 11: ...larm in case of zone shorting if it has been EOL programmed To enable Tamper zone as 24H zone refer to address 075 1 Upon Tamper alarm a t displayed followed by the zone number To disable Tamper alarm...

Страница 12: ...7 R51 R53 RF4 VA9 R59 D20 Q1 CBE R41 D19 R40 F11 RN1 R52 R60 F3 D18 12V VA2 VA1 U2 U1 R16 R14 R13 R12 R11 R10 R9 R8 R7 R6 R5 R4 R3 R2 R1 C1 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 12V AV GAD A...

Страница 13: ...program zones 1 16 set as Zone in Use 2 3 AV 2055 2088D Wiring The AV 2088D contains eight zone terminals Via programming the panel becomes 16 zones when zone doubling used Adding the AV 208 the panel...

Страница 14: ...connect to OR Black Power connect to Aux Power Yellow System Strobe connect to YE For proper connection refer to wiring diagrams on next page and at the end of the manual IMPORTANT Never run Keypad w...

Страница 15: ...eypad s Tamper Sw connected to zone No 1 Keypad Power Back side of AV 701TIP keypad Figure 4 Wiring Keypad AV 701TS TI AV 701TIP Panel Panel Wrong Wiring Correct Wiring Figure 5 Keypad best way wiring...

Страница 16: ...ic driver module Bella sirens are compatible and feature high sound level at very low current use Self contained Bell mode is programmable address 071 This mode allows connection of Bells or Sirens th...

Страница 17: ...V 2016 panels 30 On Output ON 31 On Output OFF 32 A1 Output ON 33 A1 Output OFF 34 A2 Output ON 35 A2 Output OFF 36 SLO Output ON37 SLO Output OFF 38 SLO1 Output ON 39 SLO1 Output OFF 40 SPARE Output...

Страница 18: ...keypad for approximately 8 hours With LCD keypad the backup time is to 6 hours AV 2016 accommodates two 12V 7 2 AH battery Do not connect two batteries in series or parallel Contact us for instructio...

Страница 19: ...8NW TFB 110 TFB 110 Reset Switch or Relay Module V V at alarm V via the Reset Switch V V To Zone Input Figure 6 Smoke Detector Wiring TF smoke series To reset smoke detector program the SLO AV 2055D A...

Страница 20: ...e The SVM is a high technology device electronically stores messages with or without power The SVM is as a digital message source in Series 2000 Alarm Control Panels telephone dialers or in other appl...

Страница 21: ...all users Keypad online conformation and DTMF functions history When the control panel detects the first DTMF key five short beeps at the keypads The keypad activation shows the user at the remote si...

Страница 22: ...alarm caused by open zones In this case an Alarm tune siren sound sound 2 Disarm control panel When control panel disarmed A confirmation tune followed by a disarmed tune heard Disarmed tune Five sho...

Страница 23: ...ARMED STATUS SHUNT FIRE ZONE DISPLAY EASYLOADER AV 701 AV GAD Figure 7 AV 701 Keypad Layout Common Terms in this Manual SHUNT and BYPASS are interchangeable terms Program Mode Enables features progra...

Страница 24: ...ature Yellow LED will flash h Home will be displayed for 1 second in confirmation Starting version 2 13 PRO only To activate Group Bypass II press key 0 three times To activate both group bypass group...

Страница 25: ...hin 20 seconds following hold down of key 4 5 Chime Key 5 DOOR CHIME Enables Chime when opening zone Door Chime operates on Chime programmed zones Hold down key 5 enables and disables the function Chi...

Страница 26: ...cted on same line with a fax or answering machine is to use the Answer machine bypass feature Test 7 Key 7 FAULT FIND Fault Find enables testing of all detection devices Fault Find mode is accessible...

Страница 27: ...power fail An AC fail event displayed during history events Event AV 701 702 display Time set tu Date set du Installer programming IP User programming UP Factory defaults Fd Communication to CS failur...

Страница 28: ...ck after power up After powering up system time is reset to 00 00 h will be displayed to remind user to set time h will disappear after setting the time If Auto Arming enabled the clock setting is fro...

Страница 29: ...ny key Short confirmation beep Power up Six beeps Hold down functions Long confirmation beep Faulty programming input Long beep E display Delayed Zone triggering Three long beeps Exit delay starting i...

Страница 30: ...with Group Bypass Fire LED Red AV 2016 AV 2016DP Blink slow Warning before Fire alarm Warning before Fire alarm Blink fast During and after Fire alarm During and after Fire alarm Note Troubled Zones d...

Страница 31: ...er Now selected C Communication Tests dialer and displays telephone numbers upon holding down key 6 C Communication Flashing C in display indicates telephone line trouble c Chime Upon entering Chime m...

Страница 32: ...then press key 3 5 Arming Enter the Arm Disarm code No 1 default code is 1 2 3 4 the Red Armed indicator will light up If any zone not Delayed or Follower is troubled will be displayed and system will...

Страница 33: ...Those settings procedure at PRO panels is different refer to the AV 706 7 keypad manual Automatic Arming will not operate if the system time has not been set blinking h Automatic Arming will not oper...

Страница 34: ...for such functions as opening an electric lock Code number 7 is operative during both ARM and DISARM modes confirmed by seven short beeps Code 7 drives the SLO output as Momentary output Pulse duratio...

Страница 35: ...gits eliminate confusing of index number and code 3 The two right most LEDs blink to indicate that the system is waiting for a new code 1 to 6 digits to be entered Enter the new code 4 Installer Code...

Страница 36: ...8 189 1 2 3 4 5 6 7 8 Normally Open N O 192 193 Panic Zone 196 197 In AV 2016DP Addresses 160 and 161 are Automatic Bypass not Group Bypass 2 ZONE 17 to 32 FEATURES Zone Number 17 18 19 20 21 22 23 2...

Страница 37: ...1 Enable Display troubled zones at Disarmed 1 Enable Detailed alarm history 2 Enable Test to central station each hour 2 Enable Report Opening Closing 3 Enable Self contain Bell 0V at alarm 3 Activat...

Страница 38: ...amming mode enter to address No 099 then program new codes by first entering the code index 01 02 03 User 1 code is the Master code for changing codes user 17 code is the programming code If changed c...

Страница 39: ...store zone 9 16 Address 046 1 2 3 4 5 6 7 8 ZONE 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 VALUE 1 2 3 4 5 6 7 8 Group 3 Group 4 Group 5 Report on Zone Restore zone 17 24 Address 047 Report on Zone Resto...

Страница 40: ...235 237 239 241 243 245 247 ADDRESS 249 251 253 255 257 259 261 263 265 267 269 3 3 3 3 3 3 3 3 1st DIGIT CODE 3 3 3 3 3 3 3 3 F F 2 234 236 238 240 242 244 246 248 ADDRESS 250 252 254 256 258 260 262...

Страница 41: ...ER 9 10 11 12 13 14 15 16 Test 430 432 434 436 438 440 442 444 ADDRESS 446 448 450 452 454 456 458 460 494 C C C C C C C C 1st DIGIT CODE C C C C C C C C A 431 433 435 437 439 441 443 445 ADDRESS 447...

Страница 42: ...nked Partition No 01 Partition number should be entered in 2 digits Group 1 Group 2 Partition User 1 8 Partition User 9 16 1 2 3 4 5 6 7 8 USER 9 10 11 12 13 14 15 16 533 534 535 536 537 538 539 ADDRE...

Страница 43: ...digit can be any digit and the system will disregard the 4th digit TEL 3 COMMUNICATOR SUBSCRIBER ID CODES Group 1 Group 2 Group 3 Group 4 Group 5 Users 1 9 Users 9 16 Alarm Restore ID Alarm Restore I...

Страница 44: ...time in two digits e g for two seconds enter 0 and then 2 Address 074 and 075 manage five different features that specify the alarm outputs upon Panic and Tamper alarm Note entering a 0 value at addr...

Страница 45: ...required users for each partition The default is users 1 to 16 to Arm and Disarm partition No 01 Table 13 Addresses 550 to 605 the time set for each timer and selects which partition will be Armed and...

Страница 46: ...ffects only Instant Zone Starting version 2 16 this feature canceled Code 8 as One Time Code This feature enables user code no 8 as one time Arming code When this feature selected the code will be ope...

Страница 47: ...in delayed zone only for entry exit door Address 112 115 Erase Follow Me Number upon Disarming After disarming the system the Follow Me number is deleted If Erase feature is not programmed the Follow...

Страница 48: ...Upon Group Bypass activation the Yellow LED flashes and h Home is displayed for 1 second Group Bypass via code is optional refer to address 071 also see Section III Green Reset Zone This feature disab...

Страница 49: ...ess 065 On Siren Time Determines siren sounding period during the alarm cycle Programming a value of 0 will render audible in all types of zones Recommended and default value 15 Address 064 Outputs De...

Страница 50: ...me Determines the duration of the alarm when zones are activated Fire and Panic alarm issues a modulated 2 tone siren 24H and Burglary alarm issues a modulated 3 tone siren Modulated tones are disable...

Страница 51: ...ed to bypass zones by wire or End of Line Resistor Address 100 103 2 7 Step By Step Programming Entering Installer Engineer Programming Mode Via AV 701 or AV 702 Keypad Easy Tip You may program any ad...

Страница 52: ...e duration default 4 minutes 2 Address 063 represents the Siren Time 3 Press 0 Shunt 6 Telephone 3 Status current value of the address is 04 3 LEDs will blink and 04 will be displayed default program...

Страница 53: ...f the receiver format is Radionics Fast for Tel No 2 enter 02 in address 201 Most important parameters are the Receiver Format Handshake frequency and Data Format Data Format This parameter describes...

Страница 54: ...ing for specific user erase the user Closing or Opening code The system will check for non reporting programming and will not initiate dialing if the user is programmed for non reporting of Opening or...

Страница 55: ...system programming settings 1 Enter program mode 2 Go to address 200 and enter 6 and 9 Display will show E P R and system will revert to factory default program Code No 1 is 1 2 3 4 programming code w...

Страница 56: ...g attempts cycles is programmable at address 087 In case first central station telephone number Tel 2 does not get Kiss Off after several attempts the system will dial the back up number Tel 3 Program...

Страница 57: ...r Programming of Follow Me Telephone Number To program the Follow Me number disarm the system USE mode 1 Hold down key 6 twice wait for the blinking of 3 LEDs 2 Enter Telephone Number maximum 16 digit...

Страница 58: ...y drive A or B and type A or B At prompter A type AVGAD217 AVGAD217 is the file name The installation program will guide you and will install EasyLoad automatically by creating a new directory on your...

Страница 59: ...the computer s modem The communication program then informs you that connection to the panel established A few moments later it will disconnect because there is no response from panel If you usually d...

Страница 60: ...ones and pay attention to the sound because in its special operating mode the modem cannot detect BUSY and other call progress signals The PC modem will hang up automatically if it does not get an ans...

Страница 61: ...isconnect from the main menu Control panel status after disconnection A remote PC might connect the control panel while unattended by the owner the following must be taken in account The panel will al...

Страница 62: ...programming mode In programming mode P is displayed type 77 at address 200 i e type 20077 before attempting to establish connection When using the AV 232 interface the transfer rate is eight times fa...

Страница 63: ...Partition 1 common partition are only released upon disarm by a user assigned to partition 1 or by disarming globally using user 1 code Each partition can include Delayed and Following zones They wil...

Страница 64: ...Group Bypass User 01 may display Status of all partitions Status of all zones in all partitions Bypassed zones in partition currently disarmed short history of all partitions detailed long history di...

Страница 65: ...nuously disarming Arming via Key switch and key 5 The control panel may be Armed or Disarmed also by KEY if feature is enabled The key change affects all the partitions It is similar to an Arming or D...

Страница 66: ...eans other user code DDDD means Dealer code Pressed together the and will start a PANIC alarm H displayed This sets the alarm in partition 01 To disable Panic alarm enter Code No 01 or any user that h...

Страница 67: ...tion associated to a user Enter a two digit number in the range 01 08 in these locations Note No matter what value is entered for user 01 it will always be considered as set to 1 Programming partition...

Страница 68: ...Some zones are bypassed Blink slow Group bypass entered Group bypass in some partition Blink slow 8 seconds after Armed with Group Bypass 8 seconds after Armed with Group Bypass Fire LED Red AV 2016 A...

Страница 69: ...to 00 to disable or 01 to enable 01 by default Procedure 1 Address 092 set to 01 2 Enter User 01 code 1234 by default hold down key 8 3 u is displayed 4 Enter 66 A displayed and few beeps in confirma...

Страница 70: ...ing Panic alarm address should have a value greater than 0 zero See address 050 No siren upon alarm at troubled zone Programming Siren fuse Alarm device blown Siren time out addresses should have a va...

Страница 71: ...wer down and wait In alarm mode Aux power drops below 10V Aux power overloaded If current consumption of Aux power exceeds max rate add external power supply AV 21 No Entry delay Key 4 delete delays w...

Страница 72: ...efer to Resetting Codes to Default feature page 30 Panel s PCB is getting hot system doesn t function normally AC power is too high Power supply overloaded or faulty battery shorten Measure the low AC...

Страница 73: ...ete Chime Test Program Reset Shunt Telephone ZONE DISPLAY EASYLOADER AV 701 AV GAD PHONES TEL LINE AV GAD AV GAD 220V Fuse 0 5A A1 Remote Indication A2 Remote Indication SLO 1 Selective Indication ON...

Страница 74: ...ontact ID 54 D Data Format 53 Day Zone 46 Default Programming Setting 55 Default Programming Table 43 Delay Delete 25 Delayed Zone 46 Dial Parameters 46 Dialer 8 Dialer Test 25 Dialing Default 8 Digit...

Страница 75: ...et Events Memory 28 Reset for Smoke Detectors 47 Reset Functions 26 Resistor EOL 8 S Shunt 23 Shunt Display 25 Single Digit Format 53 Siren Test 25 Siren Test upon Arming 46 Smoke Detector Reset 47 So...

Страница 76: ...xtend beyond the description of the face hereof There is no express or implied warranty of merchantability or a warranty of fitness for particular purpose Additionally this warranty is in lieu of all...

Отзывы: