AUX air conditioner service manual
49
⑾
Anti-high temperature protection
:
①
when run on Heating mode
,
if TE
≥
57
℃
and continuously last 10 seconds, the outdoor fan stops; if
TE
≥
64
℃
and last for 10s
,
the compressor stops again
;
When TE< 52
℃
and satisfying 3minutes
protection delay condition, the compressor resume normal work.
。
②
Such temperature protection is valid only if the TE sensor works normally.
⑿
The defrosting function under heating mode
①
When the outdoor sensor in good condition, the defrosting process starts, and the sleeping light is
twinkling
:
a)TW
≤
-6
℃
and continuously last for 2minutes
;
b)The accumulated operation time of the compressor is over than 50 minutes, the interval time
between defrosting process is 50 minutes(the accumulated time shall be recalculated if power off or
remote control off ), the continuous working time of the compressor is over 5 minutes.
Once the defrosting process starts, the compressor, the indoor fan and outdoor fan turn off, and the
four-way valve turns off after 30 seconds, and after another 15 seconds the compressor turns on and
starts the defrosting process.
②
The defrosting process ending condition
:
(
The defrosting process will quit if one of the below
conditions to be satisfied
)
a) Outdoor coil
≥
12
℃;
b) Defrosting process last for 12minutes
;
c) The defrosting process quits once change modes or air-conditioner turns off by remote control.
After the defrosting process, the compressor turns off and the outdoor fan turns on; After 55 seconds,
the four-way valve turns on; after another 5 seconds, the compressor turns on; the air-conditioner
resume the normal heating process, the indoor fan runs in the mode of anti-cold wind.
⑻
Auxiliary electric heating function
a)When heating mode working normally, e.g. the compressor starts and the outdoor fan runs and the
four-way valve is electrified and the indoor fan starts, the electric heating starts if satisfying the below
conditions:
A
、
TE < 48
℃;
B、
TA < 22
℃;
C、
TS – TA
≥
3
℃;
D
、
The compressor runs continuously for 4 minutes with the heating mode;
②
The auxiliary electric heating quit operation if satisfying one of the below conditions
:
A
、
TA > 22
℃;
B
、
TS – TA < 2
℃;
C
、
TE > 52
℃;
③
If anyone of the compressor, four-way valve and indoor fan doesn’t work or fault feedback from the
indoor fan, the auxiliary electric heating quit operation
;
④
The auxiliary electric heating may be allowed to restart after 1 minutes rest if the auxiliary electric
Содержание E Series
Страница 1: ......
Страница 32: ...AUX air conditioner service manual The other parts 29 ...
Страница 33: ...AUX air conditioner service manual 30 ...
Страница 102: ...AUX air conditioner service manual 99 Outdoor unit exploded picture ...
Страница 104: ...AUX air conditioner service manual 101 2 ASW H09A4 EC Indoor unit exploded picture ...
Страница 106: ...AUX air conditioner service manual 103 Outdoor unit exploded picture ...
Страница 108: ...AUX air conditioner service manual 105 3 ASW H12A4 ET Indoor unit exploded picture ...
Страница 110: ...AUX air conditioner service manual 107 Outdoor unit exploded picture ...
Страница 112: ...AUX air conditioner service manual 109 4 ASW H12A4 EC Indoor unit exploded picture ...
Страница 114: ...AUX air conditioner service manual 111 Outdoor unit exploded picture ...
Страница 116: ...AUX air conditioner service manual 113 5 ASW H18B4 ET Indoor unit exploded picture ...
Страница 118: ...AUX air conditioner service manual 115 Outdoor unit exploded picture ...
Страница 120: ...AUX air conditioner service manual 117 6 ASW H24B4 ET Indoor unit exploded picture ...
Страница 122: ...AUX air conditioner service manual 119 Outdoor unit exploded picture ...
Страница 124: ...AUX air conditioner service manual 121 Section two H series products 1 ASW H09A4 HSF Indoor unit exploded picture ...
Страница 126: ...AUX air conditioner service manual 123 Outdoor unit exploded picture ...
Страница 128: ...AUX air conditioner service manual 125 2 ASW H09A4 HSL Indoor unit exploded picture ...
Страница 130: ...AUX air conditioner service manual 127 Outdoor unit exploded picture ...
Страница 132: ...AUX air conditioner service manual 129 3 ASW H09A4 HS Indoor unit exploded picture ...
Страница 134: ...AUX air conditioner service manual 131 Outdoor unit exploded picture ...
Страница 136: ...AUX air conditioner service manual 133 4 ASW H18B4 HS Indoor unit exploded picture ...
Страница 138: ...AUX air conditioner service manual 135 Outdoor unit exploded picture ...
Страница 140: ...AUX air conditioner service manual 137 5 ASW H24B4 HS Indoor unit exploded picture ...
Страница 142: ...AUX air conditioner service manual 139 Outdoor unit exploded picture ...
Страница 146: ...AUX air conditioner service manual 143 Outdoor unit exploded picture ...
Страница 148: ...AUX air conditioner service manual 145 2 ASF H41A5 C Indoor unit exploded picture ...
Страница 149: ...AUX air conditioner service manual 146 ...
Страница 151: ...AUX air conditioner service manual 148 Outdoor unit exploded picture ...
Страница 166: ...AUX air conditioner service manual 163 ...
Страница 240: ......