![AUX E Series Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/aux/e-series/e-series_service-manual_3023633050.webp)
AUX air conditioner service manual
47
The setting temperature can be decided and adjusted by the remote control within the control range of
16
℃
- 32
℃
through the button of temp. Add “+” and temp. Reduce “-”. Press the button “wind speed
option” to choose the wind speed among the options of automatic fan, high fan, middle fan and mute
fan. The other conditions refer to the following:
⑴
When TA-3-TS
≤
-1
℃,
if satisfying the 3 minutes protection delay condition for compressor, the
compressor and outdoor fan start, and the indoor fan runs in accordance with the anti-cold wind
condition.
W
⑵
hen TA-3-TS
≥
1
℃,
if satisfying the 3 minutes protection delay condition for compressor
,
the
compressor and outdoor fan stop working, and the indoor fan runs in accordance with the anti-cold
wind condition.
⑶
When TA-3=TS
,
remain the previous status
;
⑷
Temperature display has the temperature compensation of 3
℃
A
⑸
utomatic wind speed control
:
TA
<
TS
,
run at high fan speed
;
TS
≤
TA
<
TS +2
℃,
run at middle fan speed
;
TA
≥
TS + 2
℃,
run at low fan speed
;
There is no 3 minutes protection delay when the wind speed turns to high fan from the low fan; there
is 3 minutes protection delay when the wind speed turns to low fan from the high fan;
W
⑹
hen heating process ongoing, the button of “Swing” can control the swing leaves to swing or
stop
;
⑺
Being electrified initially, the compressor has no 3 minutes protection delay. The compressor starts
10 seconds later after the start of the four-way valve, and the outdoor fan starts 2 seconds later after
the start of the compressor; Set the TS
<
TA-3 by remote control
,
the compressor stops immediately
and without the 3 minutes protection delay;
⑻
This mode includes the timing function, sleeping function, auto-restart (optional), negative ion
(optional), I feel
(
optional
)
.
⑼
Being electrified initially, the four-way valve starts immediately ,and the compressor starts 10
seconds later; During the operation condition of the compressor, the four-way valve stops after
2min50s protection delay when stops the air-conditioner or switch mode;
In the case of compressor stops, the four-way valve stops immediately once stopping the
air-conditioner
;
⑽
Anti-cooling wind and residual-heat Removing function:
The wind speed of the indoor fan is controlled by TE, and the specific conditions are as below:
Anti-cold wind when compressor runs
:
Содержание E Series
Страница 1: ......
Страница 32: ...AUX air conditioner service manual The other parts 29 ...
Страница 33: ...AUX air conditioner service manual 30 ...
Страница 102: ...AUX air conditioner service manual 99 Outdoor unit exploded picture ...
Страница 104: ...AUX air conditioner service manual 101 2 ASW H09A4 EC Indoor unit exploded picture ...
Страница 106: ...AUX air conditioner service manual 103 Outdoor unit exploded picture ...
Страница 108: ...AUX air conditioner service manual 105 3 ASW H12A4 ET Indoor unit exploded picture ...
Страница 110: ...AUX air conditioner service manual 107 Outdoor unit exploded picture ...
Страница 112: ...AUX air conditioner service manual 109 4 ASW H12A4 EC Indoor unit exploded picture ...
Страница 114: ...AUX air conditioner service manual 111 Outdoor unit exploded picture ...
Страница 116: ...AUX air conditioner service manual 113 5 ASW H18B4 ET Indoor unit exploded picture ...
Страница 118: ...AUX air conditioner service manual 115 Outdoor unit exploded picture ...
Страница 120: ...AUX air conditioner service manual 117 6 ASW H24B4 ET Indoor unit exploded picture ...
Страница 122: ...AUX air conditioner service manual 119 Outdoor unit exploded picture ...
Страница 124: ...AUX air conditioner service manual 121 Section two H series products 1 ASW H09A4 HSF Indoor unit exploded picture ...
Страница 126: ...AUX air conditioner service manual 123 Outdoor unit exploded picture ...
Страница 128: ...AUX air conditioner service manual 125 2 ASW H09A4 HSL Indoor unit exploded picture ...
Страница 130: ...AUX air conditioner service manual 127 Outdoor unit exploded picture ...
Страница 132: ...AUX air conditioner service manual 129 3 ASW H09A4 HS Indoor unit exploded picture ...
Страница 134: ...AUX air conditioner service manual 131 Outdoor unit exploded picture ...
Страница 136: ...AUX air conditioner service manual 133 4 ASW H18B4 HS Indoor unit exploded picture ...
Страница 138: ...AUX air conditioner service manual 135 Outdoor unit exploded picture ...
Страница 140: ...AUX air conditioner service manual 137 5 ASW H24B4 HS Indoor unit exploded picture ...
Страница 142: ...AUX air conditioner service manual 139 Outdoor unit exploded picture ...
Страница 146: ...AUX air conditioner service manual 143 Outdoor unit exploded picture ...
Страница 148: ...AUX air conditioner service manual 145 2 ASF H41A5 C Indoor unit exploded picture ...
Страница 149: ...AUX air conditioner service manual 146 ...
Страница 151: ...AUX air conditioner service manual 148 Outdoor unit exploded picture ...
Страница 166: ...AUX air conditioner service manual 163 ...
Страница 240: ......