![AUX E Series Скачать руководство пользователя страница 76](http://html.mh-extra.com/html/aux/e-series/e-series_service-manual_3023633076.webp)
AUX air conditioner service manual
73
☆
When heating turns off
:
A
、
If TE
≥
TE5
,
the indoor fan unit runs at the low fan speed for 10 seconds.
B
、
If TE
<
TE5
,
the indoor fan unit closes.
⑤
Ventilating mode
a)When ventilating
,
only display the indoor temperature but without the setting temperature and its
display.
b)When ventilating
,
the temperature setting “plus” and “minus” are invalid, the functions of strong fan
and sleeping are invalid, too.
c)When ventilating
,
the indoor fan unit runs at the setting fan speed. The compressor and outdoor fan
unit close. Timing function is valid.
⑶
Control function of operation
auxiliary electric heating function
①
a) When running under heating mode, the auxiliary electric heating starts if the electric heating is
permitted by and meets the following conditions:
The compressor runs in the mode of heat pump for 4 minutes.
A.TA
≤
TA3
B.TS
-
TA
≥
3
℃
C.TE
<
TE6
b)When the auxiliary electric heating meets one of the below conditions, the auxiliary electric heating
quit
:
A.TA
≥
TA4
;
B.TS
-
TA
≤
1
℃
C.TE
≥
TE7
c) The electric heating quit once any one of the compressor and the indoor fan unit doesn’t work.
When the compressor runs, if the auxiliary electric heating quit, the electric heater can restart after 1
minute’s delay.
②
Intelligent defrosting function
a)The start condition for defrosting(The defrosting function is workable if meet one of the below
conditions
)
A
、
When start the heating mode or 5 minutes later after the defrosting process, and after the
process for catching the maximum temperature difference between the indoor coil and indoor room
temperature (last for 3 minutes), when the difference value between the indoor coil temperature and
indoor room temperature is reduced by up than 5
℃
and last for above than 3 minutes, and the
continuous running time of the compressor
>
5 minutes, the accumulated running time of the
compressor is over than 45 minutes, and the indoor coil temperature
≤
48
℃
.(When the fan speed of the
indoor fan unit falls by one gear, the correctness of the temperature difference is -2
℃
, when the fan
speed of the indoor fan unit rise 1 gear, the correctness of the temperature difference is +2
℃
).
Содержание E Series
Страница 1: ......
Страница 32: ...AUX air conditioner service manual The other parts 29 ...
Страница 33: ...AUX air conditioner service manual 30 ...
Страница 102: ...AUX air conditioner service manual 99 Outdoor unit exploded picture ...
Страница 104: ...AUX air conditioner service manual 101 2 ASW H09A4 EC Indoor unit exploded picture ...
Страница 106: ...AUX air conditioner service manual 103 Outdoor unit exploded picture ...
Страница 108: ...AUX air conditioner service manual 105 3 ASW H12A4 ET Indoor unit exploded picture ...
Страница 110: ...AUX air conditioner service manual 107 Outdoor unit exploded picture ...
Страница 112: ...AUX air conditioner service manual 109 4 ASW H12A4 EC Indoor unit exploded picture ...
Страница 114: ...AUX air conditioner service manual 111 Outdoor unit exploded picture ...
Страница 116: ...AUX air conditioner service manual 113 5 ASW H18B4 ET Indoor unit exploded picture ...
Страница 118: ...AUX air conditioner service manual 115 Outdoor unit exploded picture ...
Страница 120: ...AUX air conditioner service manual 117 6 ASW H24B4 ET Indoor unit exploded picture ...
Страница 122: ...AUX air conditioner service manual 119 Outdoor unit exploded picture ...
Страница 124: ...AUX air conditioner service manual 121 Section two H series products 1 ASW H09A4 HSF Indoor unit exploded picture ...
Страница 126: ...AUX air conditioner service manual 123 Outdoor unit exploded picture ...
Страница 128: ...AUX air conditioner service manual 125 2 ASW H09A4 HSL Indoor unit exploded picture ...
Страница 130: ...AUX air conditioner service manual 127 Outdoor unit exploded picture ...
Страница 132: ...AUX air conditioner service manual 129 3 ASW H09A4 HS Indoor unit exploded picture ...
Страница 134: ...AUX air conditioner service manual 131 Outdoor unit exploded picture ...
Страница 136: ...AUX air conditioner service manual 133 4 ASW H18B4 HS Indoor unit exploded picture ...
Страница 138: ...AUX air conditioner service manual 135 Outdoor unit exploded picture ...
Страница 140: ...AUX air conditioner service manual 137 5 ASW H24B4 HS Indoor unit exploded picture ...
Страница 142: ...AUX air conditioner service manual 139 Outdoor unit exploded picture ...
Страница 146: ...AUX air conditioner service manual 143 Outdoor unit exploded picture ...
Страница 148: ...AUX air conditioner service manual 145 2 ASF H41A5 C Indoor unit exploded picture ...
Страница 149: ...AUX air conditioner service manual 146 ...
Страница 151: ...AUX air conditioner service manual 148 Outdoor unit exploded picture ...
Страница 166: ...AUX air conditioner service manual 163 ...
Страница 240: ......