AUX air conditioner service manual
82
The temperature setting range is 16
℃~
32
℃
a)Primary setting temperature is 20
℃,
setting fan speed is middle fan
,
press” plus” and“minus”button
to adjust the setting temperature. Press the “fan speed” button to select the setting fan speed among the
low fan, middle fan and high fan speed.
b)The characteristic of control
:
TA
-
TS
≤
-
1
℃,
compressor and outdoor fan unit start.
TA
-
TS
≥
1
℃,
compressor and outdoor fan unit stop.
TA
=
TS
,
remain the previous condition.
c) The four-way valve keep open (except the defrosting condition)when running under the heating
mode. When transforming from the heating mode to the other mode or the air-conditioner turns off
with electricity, the four-way valve turns off in 2minutes delay.
d) Anti-cold air function and residual-heat removal function
Indoor fan unit control
:
The indoor fan unit is controlled according to the setting temperature, indoor
room temperature and indoor coil temperature.
☆
When compressor runs
:
A
、
when TE
≥
TE1
,
the indoor fan unit runs at the setting fan speed. If the temperature rise up to
TE1 and fall down again, the low fan speed can be restored after the temperature reach TE1-5.
B
、
when TE2
≤
TE
<
TE1
,
the indoor fan unit runs at the low fan speed. If the temperature rise up
to TE2 and fall down again, the fan stops only after the temperature reach TE2-2.
C
、
When TE
<
TE2
,
the indoor fan doesn’t start, hereafter if the coil temperature
≥
TE2
,
the fan
restore to the normal working condition.
D
、
If the indoor fan unit stop running for over than 10 minutes
,
the “heating” indication light on
the operation panel twinkles.
☆
When compressor stop running
:
A
、
If TE
≥
TE3
,
the indoor fan unit runs at the setting fan speed.
B
、
If TE4
≤
TE
<
TE3
,
the indoor fan unit runs at low fan speed.
C
、
If TE
<
TE4
,
the indoor fan unit stops running.
☆
When heating turns off
:
A
、
If TE
≥
TE5
,
the indoor fan unit runs at the low fan speed for 30 seconds.
B
、
Detect TE 30 seconds later, If TE still
≥
TE5
,
the indoor fan unit runs at low fan speed and to
be closed until TE
<
TE5.
●
Ventilation mode
a)When ventilating
,
only display the indoor temperature but without the setting temperature and its
display.
b)When ventilating
,
the temperature setting “plus” and ”minus” are invalid, the functions of strong fan
and sleeping are invalid, too.
c)When ventilating
,
the indoor fan unit runs at the setting fan speed. The compressor, four-way valve,
auxiliary electric heater and outdoor fan unit close.
Содержание E Series
Страница 1: ......
Страница 32: ...AUX air conditioner service manual The other parts 29 ...
Страница 33: ...AUX air conditioner service manual 30 ...
Страница 102: ...AUX air conditioner service manual 99 Outdoor unit exploded picture ...
Страница 104: ...AUX air conditioner service manual 101 2 ASW H09A4 EC Indoor unit exploded picture ...
Страница 106: ...AUX air conditioner service manual 103 Outdoor unit exploded picture ...
Страница 108: ...AUX air conditioner service manual 105 3 ASW H12A4 ET Indoor unit exploded picture ...
Страница 110: ...AUX air conditioner service manual 107 Outdoor unit exploded picture ...
Страница 112: ...AUX air conditioner service manual 109 4 ASW H12A4 EC Indoor unit exploded picture ...
Страница 114: ...AUX air conditioner service manual 111 Outdoor unit exploded picture ...
Страница 116: ...AUX air conditioner service manual 113 5 ASW H18B4 ET Indoor unit exploded picture ...
Страница 118: ...AUX air conditioner service manual 115 Outdoor unit exploded picture ...
Страница 120: ...AUX air conditioner service manual 117 6 ASW H24B4 ET Indoor unit exploded picture ...
Страница 122: ...AUX air conditioner service manual 119 Outdoor unit exploded picture ...
Страница 124: ...AUX air conditioner service manual 121 Section two H series products 1 ASW H09A4 HSF Indoor unit exploded picture ...
Страница 126: ...AUX air conditioner service manual 123 Outdoor unit exploded picture ...
Страница 128: ...AUX air conditioner service manual 125 2 ASW H09A4 HSL Indoor unit exploded picture ...
Страница 130: ...AUX air conditioner service manual 127 Outdoor unit exploded picture ...
Страница 132: ...AUX air conditioner service manual 129 3 ASW H09A4 HS Indoor unit exploded picture ...
Страница 134: ...AUX air conditioner service manual 131 Outdoor unit exploded picture ...
Страница 136: ...AUX air conditioner service manual 133 4 ASW H18B4 HS Indoor unit exploded picture ...
Страница 138: ...AUX air conditioner service manual 135 Outdoor unit exploded picture ...
Страница 140: ...AUX air conditioner service manual 137 5 ASW H24B4 HS Indoor unit exploded picture ...
Страница 142: ...AUX air conditioner service manual 139 Outdoor unit exploded picture ...
Страница 146: ...AUX air conditioner service manual 143 Outdoor unit exploded picture ...
Страница 148: ...AUX air conditioner service manual 145 2 ASF H41A5 C Indoor unit exploded picture ...
Страница 149: ...AUX air conditioner service manual 146 ...
Страница 151: ...AUX air conditioner service manual 148 Outdoor unit exploded picture ...
Страница 166: ...AUX air conditioner service manual 163 ...
Страница 240: ......