AUX air conditioner service manual
51
timing range is 1min.-24hour. The air-conditioner stops automatically once the setting timing reached.
②
Timing turns on
The timing turns on function can be set only under the running status of the air-conditioner. The
timing range is 1min.-24hour. The air-conditioner turns on automatically once the setting timing
reached. The turning on and turning off action happen after setting timing set will cancel the previous
set setting timing and sleeping functions
⑾
Self-detecting function
Press the Emergency button and electrify the air-conditioner, the self-detecting process starts
after the buzzer delivers short tone twice:
Start the electric heating, run the indoor fan at a high fan speed, open the air door to be the
maximum
Æ
the digital display and three indicating light on in 1 second
Æ
digital displays
“11”
、
“22”
、
“33”
、
“44” in turn and 1second for each of them
Æ
Working light on 1 second
Æ
Timing light on 1 second
Æ
Sleeping light on 1 second
Æ
Each phase of the stepping motor
moves in 1 second
Æ
the indoor fan runs for 1 second at low fan speed and middle fan speed
separately
Æ
the compressor moves for 1 second
Æ
The four-way valve moves for 1 second
Æ
Outdoor fan moves for 1 second
Æ
Negative ion generator moves for 1 second
Æ
buzzer
deliver one short tone
Æ
Electric heating runs 30 Seconds and stops, then the air conditioner
turn into the waiting status, the self-testing is ended.
⑿
Fault indication
When there is faults happen to the air-conditioner, the timing lights on the display panel will indicate
the corresponding fault codes, which are specifically reflected as the following:
For LED display:
FAULT DISPLAY
MODE DISPLAY
PRIORITY
APPEARANCE
TA
abnormity
Timer lamp flash
1
times/8 seconds
2 AC
stopped
TE
abnormity
Timer lamp flash
2
times/8 seconds
3 AC
stopped
TW
abnormity
Timer lamp flash
8
times/8 seconds
4
AC hasn’t stopped
For Digital display:
FAULT DISPLAY
MODE
DISPLAY
PRIORITY
APPEARANCE
TA abnormity
display“E1”
2
AC stopped
TE abnormity
display “E3”
3
AC stopped
TW abnormity
display “E2”
4
AC hasn’t stopped
⒀
The definition of the swing angle
(Picture 3)It shows the swing angles of the types 18000BTU and 24000BTU stepping motor
,
the air
Содержание E Series
Страница 1: ......
Страница 32: ...AUX air conditioner service manual The other parts 29 ...
Страница 33: ...AUX air conditioner service manual 30 ...
Страница 102: ...AUX air conditioner service manual 99 Outdoor unit exploded picture ...
Страница 104: ...AUX air conditioner service manual 101 2 ASW H09A4 EC Indoor unit exploded picture ...
Страница 106: ...AUX air conditioner service manual 103 Outdoor unit exploded picture ...
Страница 108: ...AUX air conditioner service manual 105 3 ASW H12A4 ET Indoor unit exploded picture ...
Страница 110: ...AUX air conditioner service manual 107 Outdoor unit exploded picture ...
Страница 112: ...AUX air conditioner service manual 109 4 ASW H12A4 EC Indoor unit exploded picture ...
Страница 114: ...AUX air conditioner service manual 111 Outdoor unit exploded picture ...
Страница 116: ...AUX air conditioner service manual 113 5 ASW H18B4 ET Indoor unit exploded picture ...
Страница 118: ...AUX air conditioner service manual 115 Outdoor unit exploded picture ...
Страница 120: ...AUX air conditioner service manual 117 6 ASW H24B4 ET Indoor unit exploded picture ...
Страница 122: ...AUX air conditioner service manual 119 Outdoor unit exploded picture ...
Страница 124: ...AUX air conditioner service manual 121 Section two H series products 1 ASW H09A4 HSF Indoor unit exploded picture ...
Страница 126: ...AUX air conditioner service manual 123 Outdoor unit exploded picture ...
Страница 128: ...AUX air conditioner service manual 125 2 ASW H09A4 HSL Indoor unit exploded picture ...
Страница 130: ...AUX air conditioner service manual 127 Outdoor unit exploded picture ...
Страница 132: ...AUX air conditioner service manual 129 3 ASW H09A4 HS Indoor unit exploded picture ...
Страница 134: ...AUX air conditioner service manual 131 Outdoor unit exploded picture ...
Страница 136: ...AUX air conditioner service manual 133 4 ASW H18B4 HS Indoor unit exploded picture ...
Страница 138: ...AUX air conditioner service manual 135 Outdoor unit exploded picture ...
Страница 140: ...AUX air conditioner service manual 137 5 ASW H24B4 HS Indoor unit exploded picture ...
Страница 142: ...AUX air conditioner service manual 139 Outdoor unit exploded picture ...
Страница 146: ...AUX air conditioner service manual 143 Outdoor unit exploded picture ...
Страница 148: ...AUX air conditioner service manual 145 2 ASF H41A5 C Indoor unit exploded picture ...
Страница 149: ...AUX air conditioner service manual 146 ...
Страница 151: ...AUX air conditioner service manual 148 Outdoor unit exploded picture ...
Страница 166: ...AUX air conditioner service manual 163 ...
Страница 240: ......