![AUX E Series Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/aux/e-series/e-series_service-manual_3023633070.webp)
AUX air conditioner service manual
67
2. Mode button: used for selecting the working mode of the air-conditioner (the option working mode
of two pump type includes cooling, dehumidifying, heating and ventilating; The option working mode
of cooling only type includes cooling, dehumidifying and ventilating)
3. Wind grid button: used for selecting the mode of swing, stop and the swing direction of wind grid.
Every press on this button, the setting wind grid transforms in cycle according to the following
sequence: grid swings up and down-right and left
→
grid is fixed
→
grid swings right and left
→
grid is
fixed
→
grid swings up and down
→
grid is fixed;
4. Wind speed button: used for selecting the fan’s speed (includes the conditions of high fan and low
fan)
5. On-off button: used for controlling the start and close of the air-conditioner.
6. Remote signal receiving window: used for receiving the signal delivered from the remote controller;
●
Fluorescence display
a.- silence b-strong fan speed c. Fan speed
d-cooling e-dehumidifying f- ventilating
g-heating (invalid for cooling type) h-humidifying l-sleep
j-lock k-swing right and left L-health
m-humidity n-timing on/off O-temperature
P- up and down grid
Ⅳ
Functions for the controller of the Floor-standing unit
●
Z, C series
1. The basic working conditions for the operation of the controller
⑴
The applicable voltage range of the electrical power: The input voltage 175 V – 253V;
⑵
The input AC current frequency: 50Hz
;
⑶
The operating temperature for electric control:
(
-10~+70
)
;
℃
⑷
The operating moisture for electric control: RH20%~RH90%;
⑸
The indoor fan: three speeds tap ironclad motor; indoor fan motor relay (220VAC/5A)×3;
⑹
The outdoor fan: tap ironclad motor, only one speed and the outdoor fan relay (220VAC/5A)×1;
⑺
Four-way valve relay (220VAC/5A)×1;
⑻
The Swing Motor is synchro motor : relay (220VAC/5A)×2;
The compressor control of 51 series model is the direct relay control (220VAC/30A, 220VAC/15A)
COS
¢
=0.4
)
×1
;
The compressor control of 61,71 series model is the AC contactor (220VAC/5A
)
×1
of the compressor’s relay control (220VAC/5A)×1
;
⑼
Auxiliary electric heating relay (220VAC/30A)X1;
⑽
The model of temperature sensor of the indoor temperature and indoor coil temperature: B
(
25/50
)
=3470×
(
1±1
﹪)
K
,
R
(
25
)
=5×
(
1±1
﹪)
K
Ω
.
2. Partition of the controller’s function
⑴
The function of the controller consists of the following parts:
⑵
The buzzer’s driving function;
Содержание E Series
Страница 1: ......
Страница 32: ...AUX air conditioner service manual The other parts 29 ...
Страница 33: ...AUX air conditioner service manual 30 ...
Страница 102: ...AUX air conditioner service manual 99 Outdoor unit exploded picture ...
Страница 104: ...AUX air conditioner service manual 101 2 ASW H09A4 EC Indoor unit exploded picture ...
Страница 106: ...AUX air conditioner service manual 103 Outdoor unit exploded picture ...
Страница 108: ...AUX air conditioner service manual 105 3 ASW H12A4 ET Indoor unit exploded picture ...
Страница 110: ...AUX air conditioner service manual 107 Outdoor unit exploded picture ...
Страница 112: ...AUX air conditioner service manual 109 4 ASW H12A4 EC Indoor unit exploded picture ...
Страница 114: ...AUX air conditioner service manual 111 Outdoor unit exploded picture ...
Страница 116: ...AUX air conditioner service manual 113 5 ASW H18B4 ET Indoor unit exploded picture ...
Страница 118: ...AUX air conditioner service manual 115 Outdoor unit exploded picture ...
Страница 120: ...AUX air conditioner service manual 117 6 ASW H24B4 ET Indoor unit exploded picture ...
Страница 122: ...AUX air conditioner service manual 119 Outdoor unit exploded picture ...
Страница 124: ...AUX air conditioner service manual 121 Section two H series products 1 ASW H09A4 HSF Indoor unit exploded picture ...
Страница 126: ...AUX air conditioner service manual 123 Outdoor unit exploded picture ...
Страница 128: ...AUX air conditioner service manual 125 2 ASW H09A4 HSL Indoor unit exploded picture ...
Страница 130: ...AUX air conditioner service manual 127 Outdoor unit exploded picture ...
Страница 132: ...AUX air conditioner service manual 129 3 ASW H09A4 HS Indoor unit exploded picture ...
Страница 134: ...AUX air conditioner service manual 131 Outdoor unit exploded picture ...
Страница 136: ...AUX air conditioner service manual 133 4 ASW H18B4 HS Indoor unit exploded picture ...
Страница 138: ...AUX air conditioner service manual 135 Outdoor unit exploded picture ...
Страница 140: ...AUX air conditioner service manual 137 5 ASW H24B4 HS Indoor unit exploded picture ...
Страница 142: ...AUX air conditioner service manual 139 Outdoor unit exploded picture ...
Страница 146: ...AUX air conditioner service manual 143 Outdoor unit exploded picture ...
Страница 148: ...AUX air conditioner service manual 145 2 ASF H41A5 C Indoor unit exploded picture ...
Страница 149: ...AUX air conditioner service manual 146 ...
Страница 151: ...AUX air conditioner service manual 148 Outdoor unit exploded picture ...
Страница 166: ...AUX air conditioner service manual 163 ...
Страница 240: ......