TD- Documentation
Mounting Instruction
Chain drive KSA xxx-24 V / 230V 219-100-0-0-1.0.doc
Page 45 of 68
Planning: Brackets Set D-1
for inward opening windows
Tandem operation
Bracket Set D-1 (Space 45mm)
min. FAH at bottom and top-hung windows
min. FAB at side-hung windows
FÜ
RA
FL
m
in
. FA
H
/
FA
B
BD
Bracket Set D-1
FÜ
0
8
16
21
Planning table
Stroke
250
400
500
600
800
1000
350/37° 350/37°
400/33°
400/33°
700/31° 700/31°
800/28°
800/28°
900/30° 900/30°
1000/27° 1000/27°
1200/28° 1200/28° 1300/26° 1300/26°
1600/28° 1600/28° 1700/25° 1700/25°
2000/25° 2000/24° 2100/24° 2100/23°
min.
F
A
H / F
A
B
data in mm
Single operation
Bracket Set D-1 (Space 45mm)
45
28
RA
FL
FA
H
FAB max. 1200
BD
X
24V DC connection
X
Y
22
28
45
Y
22
20
45
min. FAH at bottom and top-hung windows
* from stroke 600 is the use of FV necessary
data in mm
22
0
22
(from FAB >1200 FV necessary)
Stroke
Planning table
Bracket Set D-1
250
400
500
600
*800
*1000
*1500
FAH / opening angle
X Y
(min.)
468 / 54°
16
220
599 / 60°
72
297
702 / 60°
72
399
801 / 60°
171
399
1006 / 60°
276
500
1211 / 60°
374
602
1713 / 60°
621
856
X
Notes
Bore template D-1 only useable for one side!
Transfer measurements to other side.
- Covering profile not insertable!
- Cable exit always on top
- Only for drives with 24 V DC with a
max. stroke of 300 mm ( > 300 mm requires
programming Ord.no.: 524182)
- white leads must be connected
- Drilling template D-1 can be used!
-
- Adjustment screw for chain pre-tension
(Measurements coincide with drilling
template D-1)
may be turned inward for a max. of 7 turns
!
Cover profile not applicable!
only for bottom hung windows
20
13
D-1
AK
AK
34
junction box
on site
Y (
m
in
.)
19