TD- Documentation
Mounting Instruction
Chain drive KSA xxx-24 V / 230V 219-100-0-0-1.0.doc
Page 35 of 68
Assembly procedure for
Mounting brackets: A-1 / B-1 / B-2
for outward opening windows / Frame installation on HSK
Install customer-provided junction box and make electrical connection (pages 62 & 63)
- near the window / must be easily accessible later
- avoid installation area with big temperature fluctuations- danger of condensation
- mind cable length of drives, standard length approx. 5m
- Ensure that a later removal of the connection cable is possible if necessary
Check safety of assembled system
and conduct trial run
see page 61
Example of calculation
AK
max.10m
Mounting on outward opening top hung windows
in facade area
- Apply steps 1 to 7 correspondingly
(pages 32 & 33)
A
A
Chain
Mind force path diagrams on page 15
- check max. opening width and compressive
force of chain
- Adhere to min. measurements of FAB x FAH
F
A
H
FAB
Mounting on outward opening top hung windows
in roof area
- Apply steps 1 to 7 correspondingly
(pages 32 & 33)
A
Mind force path diagrams on page 15
- check max. opening width and compressive
force of chain
- Adhere to min. measurements of FAB x FAH
Chain
A
Cable conduit
surface-mounted
Cable conduit
flush-mounted
Junction box
surface-mounted
Junction box
flush-mounted
16