![AUMA TIGRON TR-M1000X Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/auma/tigron-tr-m1000x/tigron-tr-m1000x_operation-instructions-manual_3016515022.webp)
5.4.
Accessories for assembly
5.4.1.
Stem protection tube for rising valve stem
Figure 18: Assembly of the stem protection tube
[1]
Protective cap for stem protection tube (fitted)
[1]*
Option: Protective cap made of steel (screwed)
[2]
Stem protection tube
[3]
Stem protection tube adapter
[4]
Option: Protection tube made of segments with threaded sleeves
[5]
V-seal
How to proceed
1.
Screw and tighten stem protection tube [2] on stem protection tube adapter [3]
Information: A sealing ring is not required. An O-ring is provided underneath
the stem protection tube adapter.
2.
For stem protection tubes made of two or more segments:
2.1 Seal threads of segments with hemp, Teflon tape, sealing agent or thread
sealing material and fasten tightly.
2.2 Push segments down to the sleeve (connecting piece).
3.
Check whether protective cap [1] for stem protection tube is available, in perfect
condition and tightly placed on or screwed to the tube.
Risk of bending or oscillation of protection tubes exceeding a length of 2 m!
Risk of damage at stem and/or protection tube.
→
Secure protection tubes exceeding 2 m by an appropriate support.
Since the connection between stem protection tube and stem protection tube adapter
is not separately sealed, this assembly variant is NOT adapted for complete immersion
under water or other liquids.
22
TR-M30X – TR-M1000X
Assembly
TR-MR30X – TR-MR1000X