![AUMA TIGRON TR-M1000X Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/auma/tigron-tr-m1000x/tigron-tr-m1000x_operation-instructions-manual_3016515014.webp)
Weights
The actuator weight is indicated on the name plate.
➭
The
indicated weight includes the actuator weight including output drive type B1, without
handwheel. For other output drive types, consider additional weights.
Table 4:
Weights for output drive type
[kg]
Flange size
Type designation
1.1
F07
A 07.2
1.3
F10
2.8
F10
A 10.2
6.8
F14
A 14.2
11.7
F16
A 16.2
Table 5:
Weights for output drive type
[kg]
Flange size
Type designation
5.2
F10
AF 07.2
5.2
F10
AF 07.6
5.5
F10
AF 10.2
13.7
F14
AF 14.2
23
F16
AF 16.2
4.2.
Storage
Danger of corrosion due to inappropriate storage!
→
Store in a well-ventilated, dry room.
→
Protect against floor dampness by storage on a shelf or on a wooden pallet.
→
Cover to protect against dust and dirt.
→
Apply suitable corrosion protection agent to uncoated surfaces.
Risk of damage due to excessively low temperatures!
→
The actuator must may only be stored permanently at temperatures down to
–40 °C.
→
On request, the actuator may be transported in specific cases and for short
duration at temperatures down to –60 °C. Please contact the factory prior to
transport if transport temperatures fall below –40 °C.
Long-term storage
For long-term storage (more than 6 months), observe the following points:
1.
Prior to storage:
Protect uncoated surfaces, in particular the output drive parts and mounting
surface, with long-term corrosion protection agent.
2.
At an interval of approx. 6 months:
Check for corrosion. If first signs of corrosion show, apply new corrosion protec-
tion.
14
TR-M30X – TR-M1000X
Transport and storage
TR-MR30X – TR-MR1000X