Manual Weighing Controller A 810
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
Page
107
6.9. Auto Free Fall Compensation
Auto Free Fall Compensation adjust the amount of feeded ingredient in “Sequence Mode” to
automatically reduce weighing errors, reaching Final weight as close as possible.
For that procedure
-
AFFC-CN completed cycles are recorded
-
differences (error) between actual weight and Final weight is calculated each time
-
average the errors after AFFC-CN cycles
-
this average is multiplied by CPS-CE for weighting
-
result is added to CPS value.
Example:
AFFC
(3.1.8.4
page
45)
: ON
Average count of AFFC (AFFC-CN 3.1.8.5 page 45)
:
4
CPS coefficient (CPS-CE 3.1.8.6 page 45)
:
2 (0: ¼; 1: ½; 2: ¾; 3: 1)
Final
(3.2.3.2.2
page
68) : 250.0kg (code
specific)
Auto Free Fall Limit (AFFL 3.2.3.2.14 page
71)
:
1.0kg
(code
specific)
Times Actual weighing value
Error Average count of AFFC
CPS
0
(power
on)
1 250.6
0.6
1 10.0
2 250.7
0.7
2 10.0
3 250.6
0.6
3 10.0
4 250.5
0.5
4
Æ
0
10.0
2.4 / 4 = 0.6
0.6 X ¾ = 0.45 new CPS: 10.
4
5
5 250.1
0.1
1 10.45
6 250.2
0.2
2 10.45
7 251.4
(1.4)
3 10.45
8 249.9
-0.1
3 10.45
9 250.0
0.0
4
Æ
0
10.45
0.2
/
4
=
0.05
0.05 X ¾ = 0.0375 new CPS: 10.
4
875
10
250.0
0 1 10.4875
11
249.9
-0.1
2 10.4875
12
250.0
0 3 10.4875
13
251.7
(-1.7)
4 10.4875
14
250.0
0
4 10.4875
-0.1
/
4
=
-0.025
-0.025 X ¾ = -0.01875 new CPS: 10.
4
6875
Note:
The CPS is internally compared with highest precision but it is only shown in precision of scaling.