Manual of Weighing Controller A 810
Page
20
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
-
Stable (STAB)
(Pin
B9)
(low-activ)
Will set „ON“, when actual weight matches stable conditions.
Parameter that affect that condition are:
Stable number “StAN”, 3.1.1.11,
p.27;
Stable
range
“StAR”,
3.1.1.12,
p.27;
ADC sampling rate “SR”,
3.1.3.3, p.32;
Filter
component
“FC”,
3.1.3.1,
p.32;
Threshold of filter jump “FT”,
3.1.3.2, p.32;
-
Discharge
(Pin
B10)
(low-activ)
Will set „ON“, when “Complete”-signal is set in sequence-mode. Duration of that signal is set via
Discharging time “dIS-TI” (p.46).
-
Go (GO)
(Pin B11)
(low-activ)
Will set „ON“, when actual weight is between threshold underweight UN (3.2.3.2.10, p.70) and
overweight OV (3.2.3.2.9, p.70) of active codeset.
-
Complete
(Pin B12)
(low-activ)
Will set „ON“, when conditions under Complete signal output mode “CSO-MD” (3.1.6.3, p.39) are
fulfilled. Duration of that signal is set via Complete output time “COTI” (p.43).
- Sequence active
(Pin
B21)
(low-active)
Will set “ON”, when “Start”-signal is activated. Will set “OFF”, when “Complete”-signal is finished
or an error is reset.
-
Run
(Pin B22)
(low-activ)
Will set „ON“, when A810 is ready for operation.
-
Sequence error
(Pin
B23)
(low-activ)
Will set „ON“, when an error during a weighing cycle has occurred. Observation via Near zero
confirmation “NZC” (p.45) and Setpoint SP1 confirmation “SPC” (p.46) possible.
-
Weight error
(Pin B24)
(low-activ)
Will set „ON“, when an error of A810 or load cell has occured. Refer to „Description of States of
Error“ at page 112.