Manual Weighing Controller A 810
Page
54
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
F
A c t
o n A c t
o
F A c t
3.1.12. Submenu “dAC”
This submenu defines the function of the onboard digital to analogue converter for an norm standard
output of 4…20mA resp. 0…10V.
3.1.12.1. Activate DAC “Act”
This toggled decision defines whether
the output to the DA conversion is
enabled.
default setting: off
3.1.12.2. Output value select
mode “MD”
Set in the range between 0 and 2.
This selection defines whether the Gross,
Net or Tare value should be converted on
that output.
mode 0: output is Gross
mode 1: output is Net
mode 2: output is Tare
default setting: 0
3.1.12.3. Output range
definition “NI”
This toggled decision defines whether
the output range is standard
on: 4 … 20mA
off: 0 … 20mA.
default setting: on
ENT
d
A C
TARE
TARE
0
/NET
GROSS
ENT
/NET
GROSS
0
TARE
M D
0
/NET
GROSS
ENT
/NET
GROSS
0
-1
+1
0
value
incr. decr.
TARE
n
N I
ENT
o F F N I
o
N I
/NET
GROSS
0
TARE
TARE
0
/NET
GROSS