2.4. Control Output Signals
-
Setpoint1 (SP1)
(Pin
B1)
(low-activ)
Will set „ON“, if setpoint1 SP1 (3.2.3.2.7, p.69) of active codeset has been exceeded.
-
Setpoint 2 (SP2)
(Pin
B2)
(low-activ)
Will set „ON“, when setpoint2 SP2 (3.2.3.2.5, p.68) of active codeset has been exceeded.
-
Setpoint3/ Compensationpoint (SP3/CPS)
(Pin
B3)
(low-activ)
Will set „ON“, when setpoint3 SP3/CPS (3.2.3.2.3, p.68) of active codeset has been exceeded.
-
Near Zero (NZ)
(Pin
B4)
(low-activ
)
Will set „ON“, when actual weight has gone below Near Zero value (3.2.3.2.13, p.71) of active
codeset.
-
Under (LO>)
(Pin
B5)
(Low-aktiv)
Will set „ON“, when actual weight has gone below Final-UNDER value (3.2.3.2.10, p.70) of active
codeset.
-
Over (<HI)
(Pin
B6)
(low-activ)
Will set „ON“, when actual weight has exceeded Final+OVER value (3.2.3.2.9, p.70) of active
codeset.
-
Lower Limit (LO LIM)
(Pin B7)
(low-activ)
Will set „ON“, when actual weight has gone below Lower Limit value (3.2.3.2.12, p.70) of active
codeset.
-
Upper Limit (HI LIM)
(Pin
B8)
(low-activ)
Will set „ON“, when actual weight has exceeded Upper Limit value (3.2.3.2.11, p.70) of active