Manual Weighing Controller A 810
Page
28
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
b A S I
C
3.1.1.15. Enable quickstart
“EnQS”
This toggled decision defines whether the
Power-on self test of the display is a full
version (OFF) or just limited to a short
segment test (ON).
default setting: off
3.1.1.16. Select character of
free unit “CM1”
Sets the character at left of the unit.
Refer to appendix 7.1 ASCII-table
at page 108.
default setting: 32 (means “space”)
3.1.1.17. Select character of
free unit “CM2”
Sets the character at right of the unit.
Refer to appendix 7.1 ASCII-table
at page 108.
default setting: 32 (means “space”)
Example:
Desired measurement unit is “kp”.
-
enable free unit “FU” by setting it “ON” (3.1.1.2) then
-
left character is “k”
Æ
in submenu “CU1” select “107” and press key “ENT” then
-
right character is “p”
Æ
in submenu “CU2” select “112” and press key “ENT”
Refer to 7.1 ASCII-Table at page 108 for assigning numbers to characters.