83
3. Print Number
Please press the Setup key. This menu selection is only available when Auto Print
has been enabled, when Auto Print = ON the screen will show:
Print NO. = 0
Range : 0 - 9999
The print number is used to identify each test result. The number can be set to
match the exact serial number or some portion of actual serial number of the item
under test or just used as an identifier or tracking number. Type in the desired
starting number in the range from 0 -9999. This number will increment as each test
is performed. The next number that will be used can be viewed from this menu at
any time after a test has been completed. This number is not save as part of the
non-volatile memory setup parameters. Therefore each time the power to the
instrument is turned off, the number will be reset to 0.
4. Sample Printer Outputs
Sample printer output with the
following setup:
Auto Print = ON and
Print Mode = All and
Print No. = 1000
NO. 1000
ACW Pass 1.0s
M 1_1 5.00KV 0.000mA
NO. 1001
ACW Hi-Limit 0.5s
M 1_1 5.00KV 10.21mA
NO. 1002
ACW Pass 1.0s
M 1_1 5.00KV 0.000mA
NO. 1003
ACW Pass 1.0s
M 1_1 5.00KV 0.000mA
Sample printer output of the same
test results, but the
Print Mode = Fail. In this case the
test number of every test is printed
but fail result details are printed
only when a failure occurs.
NO. 1000
NO. 1001
ACW Hi-Limit 0.5s
M 1_1 5.00KV 10.21mA
NO. 1002
NO. 1003
Содержание 7700
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 30: ...22 Ground Fault Interrupt GFI Trip Current 450 A max AC or DC HV Shut Down Speed 1 ms ...