19.7 X.31 Test
The ARGUS will perform a “Manual X.31 Test” or, if desired, an “Automatic X.31 Test”:
In the case of an automatic test, the ARGUS will first setup the D channel connection and
then an X.31 connection. The ARGUS will then automatically clear the connection and
display the results.
In the case of a manual test, the ARGUS will setup a D channel connection and an X.31
connection. The duration of this connection is determined by the user (or the opposing
end). For the duration of the connection, the ARGUS will repeatedly send a predefined data
packet. The ARGUS will count all of the data packets sent and received and will display
(where possible) the contents of the data packets received.
Configuring the X.31 parameters
ARGUS - Main Menu.
The ARGUS stores the parameters of the
X.31 Test in the three X.31 profiles.
The default parameters can be restored at
any time (see page 361).
Mark a profile for editing. The
selected profile will be marked blue
in the display. The default profile
will be marked in the display with a
. The ARGUS will use the
parameters in the current profile for
the X.31 Test.
The ARGUS takes over the marked
profile as the default and returns to
the Settings menu.
The ARGUS saves the TEI entered and
returns to the next higher menu.
Settings
X.31 profile
TEI
X.31 profile 1
<Edit>
Enter a TEI