19 Operation on an ISDN Access
244
ARGUS 152
19.9 Automatic Performance of Multiple Tests
The ARGUS performs an automatic test series and displays the test results. The required
parameters (e.g. measurement time and error level for the BERT, see page 217) should be
checked before the automatic test series is begun.
Using the ARGUS WINplus or WINanalyse software, the test results can be saved on a
Windows PC. On the PC, WINplus / WINanalyse can be used to generate a
comprehensive report that can then be printed, sent by e-mail and/or archived. The
ARGUS automatically performs the following sequence of single tests:
On a BRI S/T
or U-interface (ARGUS in TE mode)
-
Status
-
Level measurement
-
Service check
-
BERT in an extended call to oneself
-
Supplementary service test (Suppl.serv.test)
-
CF Interrogation (Call Diversions)
-
X.31 test
On a BRI S/T or
U interface leased line (permanent circuit)
-
Level measurement
-
BERT in end-to-end mode (e.g. with a loopbox on the remote end)