![Argus 152 Скачать руководство пользователя страница 292](http://html1.mh-extra.com/html/argus/152/152_manual_2969444292.webp)
22 Copper tests
292
ARGUS 152
The configured cable types are also used for RC measurement and TDR
measurement.
List of preconfigured default wire types:
Capacitance
Sets the capacitance (operating (mutual) capacitance) per
kilometer.
Range: 35 nF/km to 100 nF/km
Default:
39 nF/km
Name
Enter the name of the wire type.
Default:
PE 0.5 AWG24
No. Name
Wire
diameter
(mm)
Line
resistance
(Ohm/km)
Mutual
capaci-
tance
(nf/km)
VoP
(%)
Note
1
PE 0.5 AWG24
0.5
80
39
66.0
Outdoor cable, Poly-
ethylene, air filled
2
PP 0.5 AWG24
0.5
80
39
66.0
Outdoor cable, Poly-
propylone, air filled
3
Pulp 0.4 AWG26 0.4
150
36
60.0
Outdoor cable, conductor
with pulp jacket, air filled
4
Pulp 0.5 AWG24 0.5
80
39
67.0
Outdoor cable, conductor
with pulp jacket, air filled
5
Pulp 0.6 AWG22 0.6
65
38
68.0
Outdoor cable, conductor
with pulp jacket, air filled
6
PIC 0.4 AWG26 0.4
150
36
64.0
Outdoor cable, conductor
with plastic jacket, air filled
7
PIC 0.5 AWG24 0.5
80
39
66.0
Outdoor cable, conductor
with plastic jacket, air filled
8
PIC 0.6 AWG22 0.6
65
38
67.0
Outdoor cable, conductor
with plastic jacket, air filled
9
PIC 0.9 AWG19 0.9
29
34
72.0
Outdoor cable, conductor
with plastic jacket, air filled
10 Jelly 0.9 AWG19 0.9
29
34
68.0
Outdoor cable, petroleum/
jelly filled cable
11
Filled 0.4
AWG26
0.4
150
36
58.0
Outdoor cable, filled
12 Filled 0.5
AWG24
0.5
80
39
60.0
Outdoor cable, filled