22 Copper tests
290
ARGUS 152
22 Copper tests
In the Access menu, ARGUS offers the menu option "Copper tests", which enables you to
investigate the physical properties of the line.
This chapter briefly describes how to use the various functions. It is not possible to describe
the interpretation of the results in the customary detail here. As the results are usually
provided in graph form, they can only be interpreted correctly in conjunction with a know-
ledge of the line being measured. ARGUS supports this using a variety of aids, such as the
Zoom and Cursor functions.
Note:
The Ethernet cable tests (including Ethernet-TDR) are described in chapter „23 Ethernet
cable tests“ (see page 339).
22.1 R measurement
When connected to the test points via the Line socket, ARGUS continuously measures
resistance and displays the results in real time.
The chapter "Configuring accesses", page 27, explains how to set up the access type
"Copper tests".
ARGUS in the status display.
Any DC voltage on the line is indicated
here.
Continued on next page
The line must be de-energised and voltage free for R measurement!
R measurement is a two-wire measurement that measures the loop
resistance (short-circuit) between Tip(a) and Ring(b).
<Setting>
Switches to Copper/cable test
settings..
<Menu>
Switches to main menu.
<Start>
Directly accesses "Single
tests" menu.
Copper tests