22 Copper tests
ARGUS 152
297
22.3 Line scope
With the line scope, ARGUS performs a real-time analysis on the connected line. The high-
ohm line scope can e.g. be patched into an existing link between modem and DSLAM.
You can display the results in either the time or frequency range (FFT).
22.3.1 Starting the line scope
Continued on
next page
The chapter "Configuring accesses", page 27, explains how to set up the access type
"Copper tests".
ARGUS status display.
Any DC voltage on the line is indicated
here.
<Menu>
<Start>
Select one of the Copper tests.
- Copper box
- R measurement
- RC measurement
- Line scope
- TDR
- etc.
Start the desired copper test directly by
selecting it.
In this example, the line scope.
The voltage on the line may not exceed 200 V DC or 100 V
pp
AC.
Switches to main menu.
Directly accesses "Single
tests" menu.