22 Copper tests
ARGUS 152
327
Two ARGUS testers are required in order to run a Line qualification. One ARGUS
(ARGUS 1) serves as a Slave (LQ slave mode) and sends the required tones. A second
ARGUS (ARGUS 2), receives these tones and displays the measurement results.
Starting Line qualification:
ARGUS 1 - LQ slave mode
Sender's specifications:
Frequency
range
Output
power
Output
impedance
ARGUS 1 waits for ARGUS 2 to be ready to receive.
4.3125 kHz to 30 MHz
max., Sends from 256 tones
(ADSL) to a max. of 4096
tones (VDSL 2).
12 dBm, 6 dBm, 0 dBm
switchable
100, 120, 135
switchable
Quit Qualification / Waiting.