![Arcteq AQ-C255 Скачать руководство пользователя страница 69](http://html1.mh-extra.com/html/arcteq/aq-c255/aq-c255_instruction-manual_2964905069.webp)
Name
Range
Step
Default
Description
Time dial
setting k 1(9)
– 2(10)
0.01...25.00
0.01
1.00
Defines the time multiplier setting for the IDMT curve. Note that this
setting is only visible when the "Point 1(9)–2(10) characteristics"
setting is set to "Two point steps" or "Two point interpolate".
IDMT Const A
1(9) – 2(10)
0.01...25.00
0.01
1.00
Defines the IDMT constant A. Note that this setting is only visible
when the "Point 1(9)–2(10) characteristics" setting is set to "Two
point steps" or "Two point interpolate".
IDMT Const B
1(9) – 2(10)
0.01...25.00
0.01
1.00
Defines the IDMT constant B. Note that this setting is only visible
when the "Point 1(9)–2(10) characteristics" setting is set to "Two
point steps" or "Two point interpolate".
IDMT Const C
1(9) – 2(10)
0.01...25.00
0.01
1.00
Defines the IDMT constant C. Note that this setting is only visible
when the "Point 1(9)–2(10) characteristics" setting is set to "Two
point steps" or "Two point interpolate".
Operating
curve test
(online)
1.00...40.00
0.01
1.00
Allows the testing of the expected operating time with the given
I
meas
/I
set
value with an online relay.
The IDMT curve formula used to calculate the segment timing behaviour is shown below:
Below is an example of the programmable curve settings with three separate operating time segments.
1. RED: I
meas
/I
set
= 1.0…2.0, IDMT IEC-NI, time dial k = 0.05, IDMT constant A = 0.14, IDMT
constant B = 0.02, IDMT constant C = 0.0001.
2. BLUE: I
meas
/I
set
= 2.0…3.0, two point interpolate, time point = 3
3. YELLOW: I
meas
/I
set
= 3.0…5.0, definite time step, the set 3.0 s is held until the I
meas
/I
set
ratio
reaches 5.0, and after that the time point = 4 is used with the time setting 0.1 s.
A
AQ
Q-C255
-C255
Instruction manual
Version: 2.06
© Arcteq Relays Ltd
IM00035
67
Содержание AQ-C255
Страница 1: ...AQ C255 Capacitor bank protection IED Instruction manual ...
Страница 2: ......
Страница 363: ...Figure 7 4 180 Example block scheme A AQ Q C255 C255 Instruction manual Version 2 06 Arcteq Relays Ltd IM00035 361 ...
Страница 384: ...Figure 8 14 202 Device installation A AQ Q C255 C255 Instruction manual Version 2 06 382 Arcteq Relays Ltd IM00035 ...