6.6.3
User defined events
The monitoring functions of the unit can also be configured for user defined events. By
default, events are de-activated (action = NONE). Contrary to unit alarms, user defined
events only work while the DC Input is switched on. This means for instance, that you
cannot detect under voltage (UVD) anymore after switching the DC Input off and the voltage
is still sinking.
The following events can be configured independently and can, in each case, trigger the
actions NONE, SIGNAL, WARNING or ALARM.
Event
Meaning
Description
Range
UVD
Under Voltage Detection
Triggers an event if the output voltage falls below
the defined threshold.
0 V...UNom
OVD
Over Voltage Detection
Triggers an event if the output voltage exceeds the
de-fined threshold.
0 V...UNom
UCD
Under Current Detection
Triggers an event if the output current falls below
the defined threshold.
0 A...INom
OCD
Over Current Detection
Triggers an event if the output current exceeds the
de-fined threshold.
0 A...INom
OPD
Over Power Detection
Triggers an event if the output power exceeds the
de-fined threshold.
0 ...PNom
Note: These events should not be confused with alarms such as OT and OVP, which are for
unit protection. User defined events can, however, if set to action ALARM, switch
off the DC Input and thus protect the load, like a sensitive electronic application.
How to configure user defined events:
1.
While the DC Input is switched off, tap the touch area
on the main
screen.
2.
On the right side, tap the arrows
to select “4.1 Event
U” or “4.2 Event I” or “4.3 Event P”.
3.
Set the monitoring limits with the left hand rotary knob and the triggered action
with the right hand knob relevant to the application (also see section 6.6.1,
“Definition of Terms” on page 87).
4.
Accept the settings with
.
Notes:
User events are an integral part of the actual user profile. Thus, if another user
profile or the default profile is selected and used, the events could either be
differently configured or not at all.
The set values can be entered using the decimal keypad. This will appear by tapping
the touch area “Direct input”.