6RL SERIES OPERATION MANUAL
SECTION 7: REMOTE PROGRAMMING
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
6RL Series Regenerative DC Load Operation Manual
Page 156 of 204
Command
Description
POWer:STAGe:AFTer:REMote˽{ AUTO | OFF }
POWer:STAGe:AFTer:REMote?
Defines, how the DC input/output of the unit shall be
after leaving remote control.
AUTO = Last condition remains
OFF = DC input/output will be switched off
SYSTem:ALARm:ACTion:PFAil˽{ AUTO | OFF }
SYSTem:ALARm:ACTion:PFAil?
Defines, how the DC input/output of the unit shall be
after a power fail (PF) alarm, which could be a mains
blackout or similar and after which the unit could
continue its work automatically.
AUTO = DC input/output condition before PF is restored
OFF = DC input/output will be switched off
7.12.13
Interface Module Commands (Excl. Ethernet)
Most of the optional interface modules can also be remotely configured using SCPI
commands, either via USB port or even via the interface itself. These settings are saved
automatically.
Command
Description
SYSTem:COMMunicate:INTerface:CODE?
Returns a value, representing a model code for the
installed Anybus interface module:
5 = Profibus
21 = Ethernet 2P
9 = RS232
22 = ModBus TCP 2P
16 = CANopen
23 = Profinet/IO 2P
18 = ModBus TCP 1P
25 = CAN
19 = Profinet/IO 1P
26 = EtherCAT
20 = Ethernet 1P
SYSTem:COMMunicate:INTerface:TYPE?
Queries the name of the installed interface module.
SYSTem:COMMunicate:INTerface:SERial?
Queries the serial number of the installed interface
module.
SYSTem:COMMunicate:INTerface:ADDRess˽<NR1>
SYSTem:COMMunicate:INTerface:ADDRess?
Sets the Profibus address of the Profibus module
IF-AB-PBUS or queries it. Allowed range: 0...125
SYSTem:COMMunicate:PROFibus:ID?
Queries the Profibus ID of the unit manufacturer.
SYSTem:COMMunicate:PROFibus:FTAG˽<SRD>
SYSTem:COMMunicate:PROFibus:FTAG?
Sets or queries the Profibus/Profinet specific “function
tag“, a string of up to 32 characters
SYSTem:COMMunicate:PROFibus:LTAG˽<SRD>
SYSTem:COMMunicate:PROFibus:LTAG?
Sets or queries the Profibus/Profinet specific “location
tag“, a string of up to 22 characters
SYSTem:COMMunicate:PROFibus:DATE˽<SRD>
SYSTem:COMMunicate:PROFibus:DATE?
Sets or queries the Profibus/Profinet specific “date tag“,
a date/time string of up to 40 characters
SYSTem:COMMunicate:PROFibus:DESCription˽<SRD>
SYSTem:COMMunicate:PROFibus:DESCription?
Sets or queries the Profibus/Profinet specific
“description“ tag, a string of up to 54 characters
SYSTem:COMMunicate:PROFibus:NAME˽<SRD>
SYSTem:COMMunicate:PROFibus:NAME?
Sets or queries the Profinet specific “station name”,
a string of up to 200 characters
SYSTem:COMMunicate:INTerface:BAUD˽<NR1>
SYSTem:COMMunicate:INTerface:BAUD?
Queries or sets the bus speed, i.e. baud rate of a
CANopen or RS232 interface module. The unit will only
save the value. This means, with value 3 being saved
and CANopen installed, it will run at
100 kbps and with RS232 installed, with 19200
Baud.
SYSTem:COMMunicate:CAN:BROadcast˽<NR1>
SYSTem:COMMunicate:CAN:BROadcast?
Sets the CAN broadcast ID for normal CAN
communication. Allowed range:
0...2047 (11 bit) resp. 0...536870911 (29 bit)