6RL SERIES OPERATION MANUAL
SECTION 7: REMOTE PROGRAMMING
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
6RL Series Regenerative DC Load Operation Manual
Page 163 of 204
Command
Description
[SOURce:]FUNCtion:GENerator:MPP:INDex˽7
[SOURce:]FUNCtion:GENerator:MPP:DATA?
Index 7: resulting MPP
Reads three values (Uact, Iact, Pact) which define
the MPP (modes 1, 2 and 4)
[SOURce:]FUNCtion:GENerator:MPP:INDex˽8
[SOURce:]FUNCtion:GENerator:MPP:LEVel[?]˽{1-100}
[SOURce:]FUNCtion:GENerator:MPP:DATA[?]˽<NRf>
Index 8: Set voltage values for mode 4
1-100: Select the value to set
Set value (0-Unom)
[SOURce:]FUNCtion:GENerator:MPP:INDex˽9
[SOURce:]FUNCtion:GENerator:MPP:LEVel[?]˽{1-100}
[SOURce:]FUNCtion:GENerator:MPP:DATA?
Index 9: Measured results of mode 4
Select measured data to read
Read data (three values: Uact, Iact, Pact)
[SOURce:]FUNCtion:GENerator:MPP:INDex˽10
[SOURce:]FUNCtion:GENerator:MPP:DATA[?]˽{5-60000}
Index 10: Regulation interval for mode 4 stepping or for
next tracking action in the other mode (this parameter is
only available in remote control; for manual control it is
set to minimum)
5-60000 ms
[SOURce:]FUNCtion:GENerator:MPP:INDex˽11
[SOURce:]FUNCtion:GENerator:MPP:DATA[?]˽{1-100}
Index 11: Start number for mode 4 of the voltage values
set with index 8
Set start number
[SOURce:]FUNCtion:GENerator:MPP:INDex˽12
[SOURce:]FUNCtion:GENerator:MPP:DATA[?]˽{1-100}
Index 12: End number for mode 4 of the voltage values
set with index 8
Set end number
[SOURce:]FUNCtion:GENerator:MPP:INDex˽13
[SOURce:]FUNCtion:GENerator:MPP:DATA[?]˽{0-65535}
Index 13: Number of repetitions for mode 4
Repetitions of the scan
7.12.16.2
Control of MPP tracking
The MPP tracking is started or stopped with a separate command. Independent from the DC
input condition of the device it would automatically switch the DC input on when sending
RUN.
Command
Description
[SOURce:]FUNCtion:GENerator:MPP:STATe[?]˽{RUN | STOP}
RUN = Runs the MPP tracking in the configured
mode
STOP = Stops MPP tracking anytime, nom matter if
there is a positive result or not
? = Read the tracking status
The tracking status, as it can be read with command FUNC:GEN:MPP:STAT?, returns the
current status as RUN (running) or STOP (stopped). The meaning of STOP slightly differs,
depending on the chosen mode:
Mode 1:
STOP means, the MPP has been found (positive result) and the tracking has
been finished
Modes 2 and 3: These modes don't stop automatically, so STOP only returns the status as
set by :STAT command
Mode 4:
STOP means, the user curve has been processed the defined number of
cycles