6RL SERIES OPERATION MANUAL
SECTION 4: TECHNICAL SPECIFICATIONS
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
6RL Series Regenerative DC Load Operation Manual
Page 33 of 204
9.3 kW
Model
6RL9-510-80-2
6RL9-210-250-2
6RL9-90-500-2
6RL9-66-750-2
6RL9-30-1500-2
Analog interface
(3
Set value inputs
U, I, P, R
Actual value output
U, I
Control signals
DC on/off, Remote on/off, R mode on/off
(4
Status signals
CV, OVP, OT
Galvanic isolation to the device
max. 1500 V DC
Sample rate (set value inputs)
500 Hz
Insulation
Input (DC) to enclosure
DC minus: permanent max. ±400 V
DC plus: permanent max. (±400 V + input voltage)
Input (AC) to input (DC)
Max. 2500 V, short-term
Environment
Cooling
Temperature controlled fans
Ambient temperature
0..50 °C
Storage temperature
-20...70 °C
Digital interfaces
Featured
1x USB-B for communication, 1x USB-A for functions and logging, 1x Master-slave bus, 1x
GPIB (optional)
Interface modules slot
(2
optional: CANopen, Profibus, Profinet, RS232, CAN, Ethernet, ModBus TCP
Galvanic isolation to the device
max. 1500 V DC
Terminals
Rear side
Share Bus, DC input, AC input/output, remote sensing, analog interface, USB-B, master-
slave bus, Interface module slot
Front side
USB-A
Dimensions
Enclosure (WxHxD)
19“ x 3U x 609 mm
Total (WxHxD)
483 mm x 133 mm x 714 mm
Standards
EN 60950, EN 50160 (grid class 2),
Weight
31 kg
31 kg
31 kg
31 kg
31 kg
1.
For technical specifications of the analog interface see section 6.5.3.4, “Analog Interface Specifications” on
page 82.
2.
Only in the standard version