6RL SERIES OPERATION MANUAL
SECTION 6: FRONT PANEL OPERATION
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
6RL Series Regenerative DC Load Operation Manual
Page 58 of 204
6.2.2
General display and setting ranges:
Display
Unit
Range
Description
Actual voltage
V
0-125% UNom
Actual value of DC input voltage
Set value voltage
(1
V
0-100% UNom
Set value for limiting the DC input voltage
Actual current
A
0.2-125% INom
Actual value of DC input current
Set value current
(1
A
0-100% INom
Set value for limiting the DC input current
Actual power
W/kW
0-125% PNom
Calculated actual value of input power,
P = UIN * IIN
Set value power
(1
W/kW
0-100% PNom
Set value for limiting DC input power
Actual resistance
Ω
x
(2
...99999 Ω
Calculated actual internal resistance,
R = UIN / IIN
Set value internal resistance
(1
Ω
x
(2
-100% RMax
Set value for the target internal resistance
Adjustment limits
A, V, W/kW
0-102% nom
U-max, I-min etc., related to the physical values
Protection settings
A, V, W/kW
0-110% nom
OVP, OCP etc., related to the physical values
1.
Valid also for values related to these physical units, such as OVD for voltage and UCD for current.
2.
Lower limit for resistance set value varies. See Technical Specifications.
6.2.3
Status Display
Display
Description
Locked
The touch interface is locked
Unlocked
The touch interface is unlocked
Remote:
The unit is under remote control from....
Analog
....the built-in analog interface
USB & others
....the built-in USB port or a plug in interface module
Local
The unit has been locked by the user explicitly against remote control
Alarm:
Alarm condition which has not been acknowledged or still exists.
Event:
A user defined event has occurred which is not yet acknowledged.
Master
Master-slave mode activated, unit is a master
Slave
Master-slave mode activated, unit is a slave
Function:
Function generator activated, function loaded
Stopped / Running
Status of the function generator resp. of the function
/
Data logging to USB stick active or failed