Command
Description
SCPI
SOURce<n>:VOLTage:PROTection:STATe?
Returns the state 1 (ON) or 0 (OFF) If the
overvoltage protection is enabled.
C
SOURce<n>:VOLTage:PROTection:CLEar
Clears the overvoltage protection circuit.
C
SOURce<n>:VOLTage:RAMP <NRf> <NRf>
Sets the output voltage to ramp from the present
value to the specified value (first argument) in the
specified time (second argument). See Ramp
Function Description Section 10.5.3.
N
SOURce<n>:VOLTage:RAMP?
Returns 1 if the ramp is in progress, and 0 if the
ramp is completed.
N
SOURce<n>:VOLTage:RAMP:ABORt
Aborts ramping and clears trigger mode.
N
SOURce<n>:VOLTage:ALL?
Returns the ramping status.
N
SOURce<n>:VOLTage:RAMP:HTRIGgered
<NRf><NRf>
Sets the value of the output voltage ramp to be
implemented when the hardware trigger is
received.
N
SOURce<n>:VOLTage:RAMP:HTRIGgered?
Returns the value of the output voltage ramp to
be implemented when the hardware trigger is
received.
N
SOURce<n>:VOLTage:RAMP:TRIGgered <NRf>
<NRf>
Sets the output voltage to ramp from the present
value to the specified value (first argument) in the
specified time (second argument) upon the
trigger command. See description of the Ramp
Function below.
N
SOURce<n>:VOLTage:RAMP:TRIGgered?
Returns the output voltage to ramp
N
SOURce<n>:VOLTage:TRIGgered <NRf>
Sets the output voltage to the values stored by
sending the command TRIGger<n>:TYPe 1 or 3.
C
SOURce<n>:VOLTage:TRIGgered?
Returns the voltage level that will be set upon
receipt of the trigger.
C
SOURce<n>:VOLTage:TRIGgered:CLEar
Clears the value stored by the
SOURce<n>:VOLTage:TRIGger:AMPLitude
command.
C
SOURce<n>:VOLTage:TRIGgered:[AMPLitude]
<NRf>
Sets the output voltage to the values stored by
sending the command TRIGger:TYPe 1 or 3.
C
SOURce<n>:VOLTage:TRIGgered:[AMPLitude]?
Returns the stored value of the output current to
be set when the
SOURce<n>:VOLTage:TRIGGered command is
sent.
C
SOURce<n>:VOLTage:PROGram <string>
Changes the Voltage programming mode of the
supply. Valid arguments are INT/0 (Internal
Digital Voltage programming)
EXT/1 (External analog Voltage programming)
ADD/2 (Add Internal and External Voltage
programming values)
N
SOURce<n>:VOLTage:PROGram?
Returns the setting of Voltage programming
mode
N
SOURce<n>:VOLTage:PROGram:FSC <NRf>
Sets the Full-Scale voltage, at which Full scale
Voltage will be programmed in external Voltage
programming Mode with voltage as programming
source. Valid Range is from 5 to 10V.
N
SOURce<n>:VOLTage:PROGram:FSC?
Returns the Full-scale Voltage, at which Full
scale Voltage will be programmed.
N
SOURce<n>:VOLTage:PROGram:FSCR <NRf>
Sets the Full Scale resistance, at which Full scale
Voltage will be programmed in external Voltage
programming Mode with Current (Resistance) as
programming source. Valid Range is from 5 to
10kOhm.
N
Содержание Sorensen Asterion DC ASM
Страница 1: ...M330517 01 Rev C Asterion DC Multioutput Series Programming Manual...
Страница 6: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C v SAFETY SYMBOLS...
Страница 17: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C xvi This page intentionally left blank...
Страница 20: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 1 3 This page intentionally left blank...
Страница 24: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 2 7 This page intentionally left blank...
Страница 26: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 3 9 This page intentionally left blank...
Страница 33: ...Asterion DC Multioutput Series Programming Manual 4 16 M330517 01 Rev C This page intentionally left blank...
Страница 38: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 5 21 This page intentionally left blank...
Страница 52: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 6 35 This page intentionally left blank...
Страница 55: ...Asterion DC Multioutput Series Programming Manual 7 38 M330517 01 Rev C This page intentionally left blank...
Страница 63: ...Asterion DC Multioutput Series Programming Manual 8 46 M330517 01 Rev C This page intentionally left blank...
Страница 73: ...Asterion DC Multioutput Series Programming Manual 9 56 M330517 01 Rev C This page intentionally left blank...
Страница 115: ...Asterion DC Multioutput Series Programming Manual 10 98 M330517 01 Rev C This page intentionally left blank...
Страница 119: ...Asterion DC Multioutput Series Programming Manual 11 102 M330517 01 Rev C This page intentionally left blank...
Страница 137: ...Asterion DC Multioutput Series Programming Manual 12 120 M330517 01 Rev C This page intentionally left blank...
Страница 145: ...Asterion DC Multioutput Series Programming Manual 13 128 M330517 01 Rev C CAL n LOCK...
Страница 159: ...Asterion DC Multioutput Series Programming Manual 13 142 M330517 01 Rev C This page intentionally left blank...
Страница 162: ...M330461 01 Rev C 14 145...