Asterion DC Multioutput Series
Programming Manual
M330517-01 Rev C
10-71
Command
Description
SCPI
SOURce<n>:CURRent:LIMit[:AMPLitude] <NRf>
Sets an upper soft limit on the programmed
output current for the supply.
C
SOURce<n>:CURRent:LIMit[:AMPLitude]?
Returns the upper soft limit on the programmed
output current for the supply.
C
SOURce<n>:CURRent:RAMP <NRf> <NRf>
Sets the output current to ramp from the present
value to the specified value (first argument) in the
specified time (second argument). See Ramp
Function description below.
N
SOURce<n>:CURRent:RAMP?
Returns 1 if the ramp is in progress, and 0 if the
ramp is completed.
N
SOURce<n>:CURRent:RAMP:ABORt
Aborts ramping and clears trigger mode.
N
SOURce<n>:CURRent:RAMP:ALL?
Returns the ramping status.
N
SOURce<n>:CURRent:RAMP:HTRIGgered <NRf>
<NRf>
Sets the value of the output current to ramp to be
implemented when the hardware trigger is
received.
N
SOURce<n>:CURRent:RAMP:HTRIGgered?
Returns the value of the output current to ramp to
be implemented when the hardware trigger is
received.
N
SOURce<n>:CURRent:RAMP:TRIGgered <NRf>
<NRf>
Sets the output current to ramp from the present
value to the specified value (first argument) in the
specified time (second argument) upon the
trigger command. See Ramp description below.
C
SOURce<n>:CURRent:RAMP:TRIGgered?
Returns the value that the output current is to
ramp to (first value) and the time that it is to ramp
(second value) upon the trigger command.
C
SOURce<n>:CURRent:TRIGgered <NRf>
Sets the output current to the values <NRf> when
TRIGger<n>:TYPe 2 or 3 is sent
C
SOURce<n>:CURRent:TRIGgered?
Returns the current level that will be set upon
receipt of the trigger.
C
SOURce<n>:CURRent:TRIGgered[:AMPLitude]
<NRf>
Sets the output current to the values <NRf> when
TRIGger<n>:TYPe 2 or 3 is sent
C
SOURce<n>:CURRent:TRIGgered[:AMPLitude]?
Returns the current level that will be set upon
receipt of the trigger.
C
SOURce<n>:CURRent:TRIGgered:CLEar
Clears the value stored by the
SOURce<n>:CURRent:TRIGger:AMPLitude
command.
C
SOURce<n>:CURRent:PROGram <string>
Changes the Current programming mode of the
supply. Valid arguments are INT/0 (Internal
Digital Current programming)
EXT/1 (External analog Current programming)
ADD/2 (Add Internal and External Current
programming values)
N
SOURce<n>:CURRent:PROGram?
Returns the setting of Current programming
mode
N
SOURce<n>:CURRent:PROGram:FSC <NRf>
Sets the Full Scale voltage, at which Full scale
Current will be programmed in external Current
programming Mode with voltage as programming
source. Valid Range is from 5 to 10V.
N
SOURce<n>:CURRent:PROGram:FSC?
Returns the Full-scale Voltage, at which Full
scale Current will be programmed.
N
SOURce<n>:CURRent:PROGram:FSCR <NRf>
Sets the Full Scale resistance, at which Full scale
Current will be programmed in external Current
programming Mode with Current (Resistance) as
programming source. Valid Range is from 5 to
10kOhm.
N
Содержание Sorensen Asterion DC ASM
Страница 1: ...M330517 01 Rev C Asterion DC Multioutput Series Programming Manual...
Страница 6: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C v SAFETY SYMBOLS...
Страница 17: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C xvi This page intentionally left blank...
Страница 20: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 1 3 This page intentionally left blank...
Страница 24: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 2 7 This page intentionally left blank...
Страница 26: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 3 9 This page intentionally left blank...
Страница 33: ...Asterion DC Multioutput Series Programming Manual 4 16 M330517 01 Rev C This page intentionally left blank...
Страница 38: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 5 21 This page intentionally left blank...
Страница 52: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 6 35 This page intentionally left blank...
Страница 55: ...Asterion DC Multioutput Series Programming Manual 7 38 M330517 01 Rev C This page intentionally left blank...
Страница 63: ...Asterion DC Multioutput Series Programming Manual 8 46 M330517 01 Rev C This page intentionally left blank...
Страница 73: ...Asterion DC Multioutput Series Programming Manual 9 56 M330517 01 Rev C This page intentionally left blank...
Страница 115: ...Asterion DC Multioutput Series Programming Manual 10 98 M330517 01 Rev C This page intentionally left blank...
Страница 119: ...Asterion DC Multioutput Series Programming Manual 11 102 M330517 01 Rev C This page intentionally left blank...
Страница 137: ...Asterion DC Multioutput Series Programming Manual 12 120 M330517 01 Rev C This page intentionally left blank...
Страница 145: ...Asterion DC Multioutput Series Programming Manual 13 128 M330517 01 Rev C CAL n LOCK...
Страница 159: ...Asterion DC Multioutput Series Programming Manual 13 142 M330517 01 Rev C This page intentionally left blank...
Страница 162: ...M330461 01 Rev C 14 145...