12. TROUBLESHOOTING
Symptom
Cause
Remedy
EMERGENCY
lamp is
illuminated.
EMERGENCY STOP button or
buttons are pressed and locked, or
ram is not at maximum opening limit.
Refer to “13. Clearing emergency
stop condition” in this Part.
Lamp of button is burnt out.
Turn off machine circuit breaker and
shop circuit breaker, and change
lamp.
POWER ON/OFF keyswitch is set to
OFF.
Turn it to ON.
Fuse is blown.
Turn off machine circuit breaker and
shop circuit breaker, and change
fuse.
Thermal relay is tripped.
Press its reset button.
Bar pedal is pressed and held.
Release it. (Unlock it or remove
obstacle.)
Excessive uneven load was applied
during bending operation.
Contact AMADA.
HYD. ON button
does not
illuminate when
pressed.
Shop circuit breaker is turned off.
Turn it on.
Pressure adjusting knob is not
tightened.
Turn it fully clockwise (+).
Hydraulic pump motor does not run.
Refer to “HYD. ON button does not
illuminate when pressed” described
above.
Hydraulic pump motor runs in
reverse direction.
Refer to “2-7. Supplying electric
power” in Part III.
Oil level in hydraulic oil tank is low.
Add oil as described in “2.
Maintaining hydraulic system” in Part
VI.
Valves or other devices are faulty.
Contact AMADA.
Ram does not
close when bar
pedal is pressed.
Pushrod is disconnected.
Contact AMADA.
Rising speed change position is not
properly set.
Set it again as described in “10-1.
Setting rising speed change position”
in this Part.
Ram does not
close fast
enough.
Rising speed change position setting
lever is faulty.
Contact AMADA.
Содержание RG35S-100
Страница 1: ...RG25 125 E02 200510 PRESS BRAKE ZII RG35S 100 OPERATOR S MANUAL...
Страница 6: ...vi...
Страница 7: ...I 1 Part I Safety 1 Safety rules I 2 2 DANGER and WARNING plates I 10...
Страница 16: ...I 10 2 DANGER AND WARNING PLATES Keep the DANGER and WARNING plates well noticeable and never remove them...
Страница 18: ...I 12...
Страница 22: ...II 4...
Страница 89: ...V 45 4 Turn the machine circuit breaker to OFF The POWER lamp extinguishes 5 Turn off the shop circuit breaker...
Страница 100: ...VI 8 4 HYDRAULIC CIRCUIT DIAGRAMS 4 1 RG35S...
Страница 102: ...VI 10 4 2 RG50 RG80 and RG100...
Страница 104: ...VI 12...
Страница 106: ...VI 14...
Страница 109: ......
Страница 110: ...AMADA COMPANY LTD 200 Ishida Isehara Kanagawa JAPAN Printed on recycled paper...