III-3
1-3. Things to be supplied by customer
Primary power cable
Four-conductor VCT cable (600V polyvinyl chloride insulated cabtyre
cable)
380/400/460 V specification
Model
Each conductor size
Current carrying
capacity
RG35S
9.1 A
RG50
2 mm
2
13.2 A
RG80
3.5 mm
2
23.0 A
RG100
8 mm
2
30.0 A
200/230 V specification
Model
Each conductor size
Current carrying
capacity
RG35S
17.0 A
RG50
3.5 mm
2
22.3 A
RG80
8 mm
2
38.0 A
RG100
14 mm
2
49.1 A