11. TURNING OFF POWER
CAUTION
O
Whenever the machine is not in use,
remove the key from the POWER ON/OFF
keyswitch, and hand it to the chief
operator for custody.
O
When the ram is positioned above the
maximum opening limit, stopping the
hydraulic pump motor opens the ram even
if the bar pedal is locked. Before
stopping the hydraulic pump motor,
unlock the bar pedal, and open the ram to
the maximum opening limit.
NOTICE
O
When stopping the machine at the end of the day’s work, turn off its power
with the ram positioned at the multiple opening limit.
Turn off the power of the machine as described below.
1
Turn up the multiple opening limit setting lever to clear the multiple
opening limit of the ram.
The ram opens to the maximum opening limits.
2
Press the HYD. OFF button.
The HYD. ON button
extinguishes, and the hydraulic
pump motor stops.
3
Turn the POWER ON/OFF
keyswitch to OFF, and remove
the key from the keyswitch.
Содержание RG35S-100
Страница 1: ...RG25 125 E02 200510 PRESS BRAKE ZII RG35S 100 OPERATOR S MANUAL...
Страница 6: ...vi...
Страница 7: ...I 1 Part I Safety 1 Safety rules I 2 2 DANGER and WARNING plates I 10...
Страница 16: ...I 10 2 DANGER AND WARNING PLATES Keep the DANGER and WARNING plates well noticeable and never remove them...
Страница 18: ...I 12...
Страница 22: ...II 4...
Страница 89: ...V 45 4 Turn the machine circuit breaker to OFF The POWER lamp extinguishes 5 Turn off the shop circuit breaker...
Страница 100: ...VI 8 4 HYDRAULIC CIRCUIT DIAGRAMS 4 1 RG35S...
Страница 102: ...VI 10 4 2 RG50 RG80 and RG100...
Страница 104: ...VI 12...
Страница 106: ...VI 14...
Страница 109: ......
Страница 110: ...AMADA COMPANY LTD 200 Ishida Isehara Kanagawa JAPAN Printed on recycled paper...