4. Programming
141
ML-2550A/2551A
Chapter 4 Laser W
elding by External Input/ Output Signals (EXTERNAL
CONTROL)
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
4
Opening the Resonator Shutter
(1) Close pin No.24 of the EXT.I/O (1) connector.
The resonator shutter is opened and the flashlamp comes on. Then, a laser light
output is enabled.
5
Setting Output Schedules (SCH.#01)
(1) Set the SCHEDULE number by combining pin No.29 to pin No.33 of the EXT.I/O
(1) connector. In this example, pin No.29 of the EXT.I/O (1) connector is put in a
closed circuit for 16 ms or more to set SCH.#01.
⇒
Refer to "SCHEDULE Number Selection" on page 131.
⇒
At delivery, the signal acceptance time (time from a signal input till establishment
of schedules) of welding schedules is set to 16 ms. Set the close circuit time
referring to this value. As the signal acceptance time, 0.1 ms, 1.0 ms, 4.0 ms,
8.0 ms, or 16.0 ms can be selected by displaying the MEMORY SWITCH screen
from the INITIALIZE screen. For details, refer to Chapter 2, "3. Changing the
Acceptance Time for Laser Start Signal/Schedule Signal" on page 111.
6
Outputting Laser Light
(1) Put pin No.20 (Laser Start) of the EXT.I/O (1) connector in a closed circuit.
Laser light is output simultaneously from Beam 1 and Beam 2.
Pin No.4 (End output) of the EXT.I/O (1) connector is put in a closed circuit for 40
ms and a signal is returned from the laser. Pin No.5 (Monitor normal output) or
pin No.6 (Monitor trouble output) of the EXT.I/O (1) connector is put in a closed
circuit for 40 ms and a signal is returned from the laser.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Laser output
End output
31 sec. max.
16.0ms or more
40
ms or more
50
ms
50
ms
Control switching
input
Ready output
SCHEDULE 1
input
Resonator shutter
input
SCHEDULE 2
input
BEAM SELECT 1
input
BEAM SELECT 2
input
Laser start input
16.0
ms or more
HV-ON
OFF
input
External input
acceptable input
Laser output
End output
40
ms or more
SCHEDULE 1
input
SCHEDULE 2
input
Laser start input
16.0
ms or more
Output
16.0
ms or more
Monitor normal
output
Monitor normal
output
Completion of charging
↓ ↓ ↓
Содержание ML-2550A
Страница 1: ...AA06M0642E 37 OPERATION MANUAL YAG LASER WELDER ML 2550A 2551A...
Страница 19: ...Introduction Part...
Страница 20: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 46: ......
Страница 57: ...Operating Part...
Страница 58: ......
Страница 116: ......
Страница 144: ......
Страница 168: ......
Страница 173: ...Maintenance Part...
Страница 174: ......
Страница 203: ...Appendixes...
Страница 204: ......