198
ML-2550A/2551A
1. Error Display and How to Take a Measure
No.
Contents of error
High
voltage
Alarm
output
Measures
01
POWER SUPPLY COVER OPENED
OFF
ON
The side cover or rear cover is removed or
their mounting screws are loosened.
Secure the covers with the screws.
02
HEAD COVER OPENED
OFF
ON
The head cover or lamp replacing cover is
removed.
Mount them.
03
EMERGENCY STOP
OFF
ON
An emergency stop signal is input. Close
the Pin No.2 and Pin No.7 of the EXT.I/O (3)
connector.
Reset the EMERGENCY STOP buttons
provided at the front surface of the main
unit and of the laser controller.
04
COOLANT LOW LEVEL
OFF
ON
Secondary cooling water volume is
insufficient.
Add cooling water. If the equipment is
swayed, the coolant level may change.
Stabilize the equipment.
05
PHASE TROUBLE
OFF
ON
Check whether a three-phase supply
voltage is input.
Check the wiring status of three phases L1,
L2, and L3.
06
OVERHEAT OF PUMP
OFF
ON
The cooler pump is overloaded.
Check whether the cooling water route is
abnormal.
09
TEMP ERROR AT BODY OR
OSCILLATOR
OFF
ON
Overheating occurs in the discharge
resistor provided in the main unit, or the
temperature in the oscillator (resonator
shutter or branch shutter) is abnormal.
After waiting for several minutes, press the
TROUBLE RESET key.
10
HIGH TEMPERATURE OF
COOLANT
OFF
ON
Primary cooling water flow rate is low or
the cooling water temperature is too high.
→ P.73
Increase the primary cooling water flow
rate. Check if the cooling water circulates
normally.
11
LOW TEMPERATURE OF
COOLANT
OFF
ON
The temperature of the secondary cooling
water is too low.
→ P.73
If the ambient temperature is low, it takes
time to raise the secondary cooling water
temperature. Wait until the secondary
cooling water temperature rises after the
power is turned on.
12
LOW FLOW RATE OF COOLANT
OFF
ON
The secondary cooling water flow rate is
low. The wire net in the oscillator or the
water filter is clogged. Dust off the wire net
or the water filter, or replace the water filter.
13
DEIONIZE TROUBLE
(****MΩ•cm)
OFF
ON
Purity of the secondary cooling water is
low. Allow the cooler to operate for 50–60
minutes. If this trouble still occurs, replace
the ionexchange resin.
Содержание ML-2550A
Страница 1: ...AA06M0642E 37 OPERATION MANUAL YAG LASER WELDER ML 2550A 2551A...
Страница 19: ...Introduction Part...
Страница 20: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 46: ......
Страница 57: ...Operating Part...
Страница 58: ......
Страница 116: ......
Страница 144: ......
Страница 168: ......
Страница 173: ...Maintenance Part...
Страница 174: ......
Страница 203: ...Appendixes...
Страница 204: ......