![Amada ML-2550A Скачать руководство пользователя страница 213](http://html1.mh-extra.com/html/amada/ml-2550a/ml-2550a_operation-manual_2915851213.webp)
Timing Chart
213
ML-2550A/2551A
2 timesharings of 2-powersharing deliveries ... Operation by external input signals
(EXTERNAL CONTROL)
The following diagram shows the lapse of time in the case where a schedule signal
input, BEAM1 to 4 are selected and laser light is output from input unit 1 to 4
respectively with a time difference by opening the resonator shutter.
*1
31s max.
Charging time. When a high voltage is turned ON and charging is completed, the
READY status is provided.
*2
Schedule signal acceptance time (time from a schedule signal input till esta
blishment of schedules)
*3
150ms or more Shutter operation time
*4
Laser start signal acceptance time (time from a signal input till an output)
*5
40ms
Time required for the end signal to be output after a laser output.
*6
40ms
Time required for outputting a signal to indicate whether the laser energy is within
the set upper limit value (HIGH) and lower limit value (LOW) of monitor output.
In *2 and *4, the acceptance time is 16 ms but can be changed to 0.1, 4.0 or 8.0 ms on the MEMORY
SWITCH screen.
Control Changeover
Input *
External Input
Receivable Output
HV-ON/OFF Input *
High Voltage ON
Output
Ready Output
Schedule 1 Input *
Schedule 2 Input *
Schedule 4 Input *
Schedule 8 Input *
Schedule 16 Input *
Resonator Shutter
Input *
Beam Select 1 Input *
Beam Select 2 Input *
Beam Select 3 Input *
Beam Select 4 Input *
Laser Start Input *
(Laser light)
End Output
Monitor Normal/
Trouble Output
(*: Operation on the user side)
ON
OFF
ON
OFF
ON
OFF
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
Charging completed
31s max. *1
The time set on the MEMORY
SWITCH screen or more *2
150ms or more *3
40ms *5
(After a laser output, the charging status may lower.)
*6
Laser beams are projected from Laser Beam Input Units 1 and 2 (Schedule 3)
Laser beams are projected from Laser Beam Input
Units 3 and 4 (Schedule 12)
The time set on the MEMORY SWITCH screen *4
The time set on the MEMORY SWITCH screen or more
Содержание ML-2550A
Страница 1: ...AA06M0642E 37 OPERATION MANUAL YAG LASER WELDER ML 2550A 2551A...
Страница 19: ...Introduction Part...
Страница 20: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 46: ......
Страница 57: ...Operating Part...
Страница 58: ......
Страница 116: ......
Страница 144: ......
Страница 168: ......
Страница 173: ...Maintenance Part...
Страница 174: ......
Страница 203: ...Appendixes...
Страница 204: ......